![Wilo Medana CH1-LC Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/wilo/medana-ch1-lc/medana-ch1-lc_installation-and-operating-instructions-manual_983172022.webp)
en
Product information
22
WILO SE 02/2021
Example:
Medana CH1-LC.404-5/E/A/10T
1
Series level (1 = entry level, 3 = standard level, 5 = premium level)
LC
L = Long shaft
C = Pump housing in cast iron
4
Delivery rate in m
3
/h
04
Number of impellers
5
Pump housing in cast iron + hydraulics in 1.4307 stainless steel
E
EPDM seal
A
A = Frequency 50 Hz / single-phase / 230 V
B = Frequency 60 Hz / single-phase / 220 V
C = Frequency 60 Hz / single-phase / 230 V
D = Frequency 50 Hz / three-phase / 400 V
E = Frequency 50 Hz / three-phase / 230 – 400 V
F = Frequency 60 Hz / three-phase / 220 – 380 V
G = Frequency 60 Hz / three-phase / 265 – 460 V
I = Frequency 60 Hz / three-phase / 460 V
10
Maximum pressure of the pump in bar
T
Screwed connections
3.2
Data table
Maximum utilisation pressure
Maximum operating pressure
See pump type key on rating plate and paragraph 3.1
Maximum suction pressure
6 bar
Notice: the suction pressure (P input) + the pressure at
zero delivery rate (P zero delivery rate) must always be
lower than the maximum authorised operating pressure
(P max). P input + P zero delivery rate ≤ P max. Refer to
the pump rating plate for the maximum operating pres-
sure: P max.
Temperature range
Fluid temperature
-20 °C to +120 °C with EPDM seals
-20 °C to +90 °C with VITON seals
(only on version L)
Ambient temperature
-15 °C to +50 °C
Electrical data
Motor protection rating
See plate
Insulation class
See plate
Frequency
See plate
Voltage
See plate
Motor efficiency
See plate
Other characteristics
Humidity
< 90 % without condensation
Altitude
≤ 1000 m (> 1000 m on request)
Noise level
Motor power (kW)
Frequency (Hz)
Phase
dB(A) at 1 m, BEP tolerance
0 – 3 dB(A)
0.37
50
3
54
0.55
50
3
54
0.75
50
3
55