Wilo fluidcontrol ek Скачать руководство пользователя страница 1

 

 

 

 
 
 
 
 
 
 
 
 

Wilo-Fluidcontrol / - EK 

D Montageanleitung 

GB Assembly 

Instructions 

Notice de montage 

NL 

Inbouw- en gebruikshandleiding 

Instrucciones de instalación y funcionamiento 

Istruzioni di montaggio, uso e manutenzione 

2 049 542 / ed04-0804 

Beépítési és üzemeltetési útmutató 

GR 

Οδηγίες

 

εγκατάστασης

 

και

 

λειτουργίας

 

Содержание fluidcontrol ek

Страница 1: ...eitung GB Assembly Instructions F Notice de montage NL Inbouw en gebruikshandleiding E Instrucciones de instalaci n y funcionamiento I Istruzioni di montaggio uso e manutenzione 2 049 542 ed04 0804 H...

Страница 2: ...1 4 3 2 5 6 12 Fig 1 10 11 9 8...

Страница 3: ...Fig 2 Fig 2...

Страница 4: ...220 240 V 50 60 Hz M 1 L1 N U V Fig 4 7 Fig 5...

Страница 5: ...erating instructions 12 Notice de montage et de mise en service 18 Inbouw en gebruikshandleiding 24 Instrucciones de instalaci n y funcionamiento 30 Istruzioni di montaggio uso e manutenzione 36 Be p...

Страница 6: ...supply Single phase 1 220 250V 50 60 Hz F L C max 10 A Enclosure IP 65 Connections suction discharge 1 BSP The shut off head generated by the applicable pump must be approx 0 5 bar higher than the 2...

Страница 7: ...hazards to persons due to electrical and or mechanical causes 2 4 Safety notes for the Operator Local regulations regarding the prevention of accidents must be observed Hazards from electrical energy...

Страница 8: ...or stop and connection box for pump and network 5 Hydraulic chamber with diaphragm 6 Compensating chamber with spring 7 Adjusting screw for starting pressure of the pump 8 Reset button St rungs quitti...

Страница 9: ...and Operating Instructions 5 Siting Installation 5 1 Installation For installation and mounting requirements refer to the pump installation and operating instructions The arrow at the housing indicat...

Страница 10: ...imum however 10 A inert Strictly adhere to local earthing regulations If required see VDE 0100 a ground fault circuit interruptor GFCI switch must be provided and installed by others 6 Commissioning F...

Страница 11: ...t button Pump does not generate sufficient pressure Leakage loss greater than 0 6 l min Pump runs irregularly defekt printed circuit board Pump does not generate sufficient pressure air Leakage loss g...

Страница 12: ...Budapest T 36 23 889500 wilo wilo hu Ireland WILO Engineering Ltd Limerick T 353 61 227566 sales wilo ie Italy WILO Italia s r l 20068 Peschiera Borromeo Milano T 39 25538351 wilo italia wilo it Kazak...

Страница 13: ...63 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 Erreichbar Mo Fr von 7 17 Uhr Wochenende und feier tags 9 14 Uhr elektroni sche Bereitschaft mit R ckruf Garantie Kundendi...