Wilo Drain VC 32 Скачать руководство пользователя страница 8

ENGLISH

– Remove the pump from the shaft and rinse it carefully using

clear water before touching it (never underestimate the risk
of infection!).

– Set the pump down, loosen the 3 filter fixing screws, remove

the base and disassemble the cover.

– If possible do not remove the impeller to clean it.

8

8 Problems, Causes and Remedies

Problems

Causes

Remedies

8.1.

Pump does not run

a) Electricity supply cut off

a) Check wires

If necessary replace fuses. 
Switch on the circuit breaker and 
mains switch.

b) Winding or cable damaged

b) Check cable resistance and if 

ecessary replace cable. 

Attention:

when replacing, 

match the phases up exactly 
according to colour.

c) Rotor blocked (motor buzzing)

c) Clean the impeller 

(see Chapter 7).

d) Motor defect

d) Replace the motor 

8.2.

Pump works 

a) Inlet filter blocked

a) Remove and clean filter

insufficiently or not at all

b) Wrong direction of rotation

b) Interchange two of the mains 

connection phases

c) Pressure pipe blocked

c) Remove and clean piping

d) Impeller blocked by foreign body

d) See 8.1-c

e) Shut-off valve on outlet side 

e) Check shut-off valve and open 

closed or not fully open.

where necessary

8.3.

Pump stops

a) Electronic installation fault

a) Check entire electronic installation

b) Pump blocked

b) See 8.1-c

c) Pump sluggish

c) See 8.1-c

If no solution can be found, please contact your plumbing and heating specialist or your nearest WILO customer services
team or representative.

Subject to technical alterations!