Installation and operating instructions • Wilo-Control EC-L • Ed.04/2022-09
13.4
Terminal diagram overview
Wiring diagram EC-L1... and EC-L2...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
30
55 56 57 58 59 60
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
1
off
4-20 mA
In
!
1
1
1
2
1+2
2
on
1
2
2
on
2
0-10 V
24 V
1
2
!
Terminal Function
Terminal Function
2/3
Output: Individual run signal pump 1
31/32
Input: Float switch or electrode “pump 2 in”
4/5
Output: Individual fault signal pump 1
33/34
Input: “High water” float switch or electrode
8/9
Output: Individual fault signal pump 2
37/38
Input: Pump 1 thermal winding monitor
10/11
Output: Individual run signal pump 2
39/40
Input: Pump 2 thermal winding monitor
13/14/15 Output: Collective run signal
41/42
Output: Analogue output for displaying the actual level
value
16/17/18 Output: Collective fault signal
45/46
Input: Level sensor 4 – 20 mA
19/20
Output: Power output
49/50
Input: Leakage detection pump 1
21/22
Input: Extern OFF
51/52
Input: Leakage detection pump 2
25/26
Input: “Dry-running protection” float switch or elec-
trode
55/56
Input: “Dry-running protection” float switch (ex-mode)
27/28
Input: “All pumps off” float switch or electrode
57/58
Input: Thermal winding monitor pump 1 (ex-mode)
29/30
Input: Float switch or electrode “pump 1 in”
59/60
Input: Thermal winding monitor pump 2 (ex-mode)
Terminal diagram EC-L3...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
30
55 56 57 58 59 60
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
85 86 87 88 89 90
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84
1
2
3
1
2
3
1+2
off
on
1
2
on
2
3
1
1
2
3
4-20 mA
In
0-10 V
24 V
!
1
2
3
Terminal Function
Terminal Function
1/2
Output: Power output
33/34
Input: “All pumps off” float switch
3/4
Output: Individual run signal pump 1
35/36
Input: “Pump 1 on” float switch
5/6
Output: Individual run signal pump 2
37/38
Input: “Pump 2 on” float switch
7/8
Output: Individual run signal pump 3
39/40
Input: “High water” float switch
11/12
Output: Individual fault signal pump 1
41/42
Input: Level sensor 4 – 20 mA
13/14
Output: Individual fault signal pump 2
47/48
Output: Analogue output for displaying the actual level
value
15/16
Output: Individual fault signal pump 3
63/64
Input: Leakage detection pump 1
17/18/19 Output: Collective run signal
65/66
Input: Leakage detection pump 2