Adjusting ambient thermostat
Set the thermostat to the desired operating temperature by turning the thermostat knob (3) - located on
the back of the appliance).
• To raise the temperature: Turn the knob counter clockwise.
• To lower the temperature: Turn the knob clockwise.
Temperature setting may be adjusted during operation. When the ambient temperature reaches the
setpoint determined on the thermostat, the heating elements will be cut. They will resume their heating
function when the ambient temperature drops below the setpoint.
9. TECHNICAL DETAILS
Specifications
EL 12
EL 20
Rated Power
10 kW
18 kW
Nominal Voltage
380 - 415 V~50Hz
380 - 415 V~50Hz
Nominal Current
15 A
26 A
Plug
Industrial plug 16 A
(3ph+N+E)
Industrial plug 32 A
(3ph+N+E)
Heat stages
5 / 7,5 / 10 kW
9 / 13,5 / 18 kW
Air Flow
600 m³/h
850 m³/h
Output temperature (ΔT)
27,3 / 40,7 / 52,2 C
36,3 / 53,9 / 70,5° C
Thermoregulator
0 - 40° C
0 - 40° C
Safety thermostat
90° C
90° C
Dimensions (L x W x H)
300 x 275 x 360 mm
300 x 275 x 360 mm
Weight
30 kg
30 kg
Noise level
56,1 dB (A)
54,8 dB (A)
- 7 of 11 -