- 6 of 14 -

2.

Stopping of the heater

Set main switch to pos. "O", or reverse the thermostat below the present state.

If the heater has been running on position "Heating" (Heizen) it has an automatic 
cooling of the heater until it completely shuts off.

Important!

Pull the main plug only after the heater has cooled down and stopped.

Before repairing or servicing always pull the main plug.

3.

Safety and control devices

In case there is no flame - for example caused by lack of fuel - the oil burner relay 
shuts off the heater. The control lamp on the side of the burner reset button lights up.

After the cause of the malfunction has been cleared the reset button can be pushed, 
and the burner can be restarted.

In case the limit switch has shut off, check the malfunction and eliminate it 
(overheating).

After eliminating of the overheating unlock the limit switch by removing the cap on the 
right side and pushing the unlocking key (after cooling down of the heater). Then screw
on the protection cap.

Room thermostat

The thermostat has a temperature regulation range of 5° C - 30° C and shuts the 
burner off after the preset temperature has been reached. The fan continues to run 
in order to cool the heater down to a temperature of appr. 30° C before it stops. After
the room temperature drops several °C the heater automatically starts running again.

Содержание 1221135

Страница 1: ...Perfection is our aim Oil Fired Heaters Operating Manual BV 135...

Страница 2: ...current emissions EN 55011 EMC Requirements DIN EN ISO 12100 Safety of machinery EN 60335 Safety of electrical machines DIN EN ISO 13857 Safety of machinery Note The observance of DIN EN ISO 13857 re...

Страница 3: ...ng without room thermostat 5 Operation Heating with room thermostat 5 Operation with warm air hose 5 2 Stopping 6 Important 6 3 Safety and control devices 6 Room thermostat 6 4 Cleaning 7 Cleaning of...

Страница 4: ...tive Therefore leave the plug into the socket When ordering spare parts please give the type serial number of the heater and the part number otherwise a correct delivery is not possible The admissible...

Страница 5: ...ite the atomized fuel The light of the flame activates the photo cell and ignition switches off automatically In case of disturbance or instable burning the flame control switches off the heater The o...

Страница 6: ...etc It is essential that there is a sufficient ventilation of the room The heater may not be worked on or transported during operation If the heater is used for drying of grain the set up has to be i...

Страница 7: ...ty kW 24 8 kcal h 21 300 Air volume m h 1 500 Pressing max total Pa 100 Max fuel consumption approx kg h 2 09 Heiz l EL or Petrolium Tank capacity Ltr 40 Dimensions L mm 1250 W mm 490 H mm 690 Weight...

Страница 8: ...uring service always obbey the surface temperature from the fuel preheating device Disconnect the heater first from the power supply and let it cool down danger of burning Operation Heating without ro...

Страница 9: ...utton lights up After the cause of the malfunction has been cleared the reset button can be pushed and the burner can be restarted In case the limit switch has shut off check the malfunction and elimi...

Страница 10: ...by removing the drain plug on the bottom of the tank Collect the dirty fuel in an external container Rinse the fuel tank several times with clean fuel no dirt particle should remain in the tank Check...

Страница 11: ...tarts shortly and Lack of fuel Check oil level in tank shutts off The red lamp lights up Air bubbles in the Check fuel suction and suction line return line Control lamp push reset button On initial st...

Страница 12: ...ons or an installed exhaust pipe as shown in the drawing Never start the heaters connected to just an exhaust pipe which has been lead through the wall Use it only with an additional exhaust pipe mini...

Страница 13: ...of the burner head Measure A 4 mm Measure B 2 mm Measure C 0 mm Measure D 9 mm Measure E Between 2 and 3 for approx 12 CO Burner Nozzle Danfoss 0 50 usgal h 80 S Pump Pressure 12 bar Adjustment of th...

Страница 14: ...nd NK Thermostat Fan THZ Tank Heating F Photocell RT Socket for thermostat STB Safety Thermostat BA Controler lower part MV Solenoid Valve HR Relays ZT Ingnition Transformer S Switch M Motor C Condens...

Страница 15: ...e 01 23 6162479 Nozzle 01 24 6162301 Burner Head 01 25 6162734 Flame Control 01 26 6162417 Bracket 01 27 6162418 Thermostat 01 28 6162419 Bracket 01 29 6162323 Combustion Chamber 01 31 6162422 Lead Th...

Страница 16: ...e 01 68 1130046 Clamp Hose 02 70 6162304 Burner Cover 01 71 6161318 Safety Thermostat 01 72 6162306 Ignition Cable 02 73 6162454 Cable with Plug 01 74 6162754 Control Box Socket 01 75 6162486 Grommet...

Страница 17: ...14 of 14 BV 135 Exploded view...

Отзывы: