![Willoughby Industries WWF-3603 Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/willoughby-industries/wwf-3603-series/wwf-3603-series_installation-and-operation-manual_982672011.webp)
Rev. 11/2016
Willoughby Industries, Inc.
TOLL FREE
(800) 428-4065
● LOCAL
(317) 875-0830
● FAX
(317) 875-0837
Page 11
www.willoughby-ind.com
Installation & Operation Manual
Stainless Steel 180° Washfountain
WWF-3603 Series
Installation Instructions (cont.)
Parts supplied:
• Valve Assembly (pre-installed)
• 3/8" x 4' Multi-Colored Water Lines
• Small Diameter Multi-Colored Pneumatic Tubing
• 1/4-20 x 1/2" security screws
• 1/4-20 tinnerman nuts
Note: Use wire tie mounts and wire ties to route
and secure wiring. Wires are long enough to
accommodate various routing paths. Longer
tubes may need to be bundled with wire ties so
they do not come in contact with sharp corners.
Piezo Push Button Actuator
Infrared Sensor Actuator
1.)
Locate the terminal block plate and attach to the pedestal using 1/4-20 x 1/2" security screws
and tinnerman nuts.
2.)
Locate the group of loose colored wires coming from the terminal block plate labeled "UPPER".
3.)
Feed 2 like-colored wires into each of the actuator housing assemblies (either the Infrared or
Piezo assemblies, whichever applies to the installation).
4.)
Plug both like-colored wires into the actuator as shown above (either wire will work on each
connector).
5.)
Locate the 3/8" multi-colored water lines. Match the color of each water line with the
corresponding color of wiring. Run the end of each water line up through the basin to the head
kit. Match the color of each water line to the spray head assembly below each actuator.
On each corresponding spray head, loosen the plastic nut on the plastic connector
and fi rmly push the water line through the plastic nut into the fi tting. Tighten the plastic nut to
secure the water line to the spray head. Repeat for each remaining water line. (**see JACO
Fitting Instructions on Page 14 for further detail).
6.)
Once all water lines have been attached to their corresponding spray heads, on each
corresponding manifolded valve assembly, loosen the plastic nut on the plastic connector and
fi rmly push the water line through the plastic nut into the fi tting. Tighten plastic nut to secure
the water line to the valve assembly. Repeat for each water line.
7.)
Connect each set of like-colored wires to each of the manifolded valves.
Step 4A: Connections for Infrared/Piezo Actuators