background image

AC2030T / AC3040T 

TOP VENT GAS WALL HEATER

CONTEMPORARY FINISH

Soft-white, powder-coat, heat-resistant finish to compliment any decor.

INTERIOR FURNACE CLEARANCES

1ʺ  

from an intersecting wall.

16ʺ  

from the top of the appliance to the ceiling or other obstructions.

48ʺ 

from the furnace front to draperies, furniture or other obstructions.  

 

or other combustibles.

2 ½ʺ  

from finished floor.

•  Read owner’s manual before using/installing.
•  Photographs are representative only.
•  Check local codes and ordinances for permitted uses.
•  Consult installation manual for clearances prior to installation.
•  We reserve the right to amend product specifications without notice.
•  Installation and servicing recommended by a qualified service person.
•  Please read the warranty for any limitations of disclaimers. All parts    
   carry a one-year limited warranty.
•  Venting must comply with the “Venting and Chimney Requirements”  
   section of the instruction manual.

Conversion Kits Available      

Settable elevation rating from sea level (0) to 4,500'                                                                                                                1/2ʺ Gas Connection

ACCESSORIES

 

REAR-OUTLET REGISTER -

 (AC2030T ONLY)

 

Register flush on rear wall, adjusts amount of heat delivered through rear  

register. Motorized rear outlet registef for increased airflow also available.

Model 6920

 - Motorized model for surface mounted  

installation. Shipping weight 1O lbs.

GAS CONVERSION KITS  

SINGLE SIDE

M117854

 - Propane Gas to Natural Gas

M117853

 - Natural Gas To Propane Gas

DOUBLE SIDED

 

M117881

 - Propane Gas to Natural Gas

M117880

 - Natural Gas To Propane Gas

OVAL-VENT STARTER KIT

 

Contains hold down plate, oval-to-round  

adapter, spacer plates and two pieces of  

2-foot lengths of oval pipe.

Model 9929

 - USA  

Model 9930

 - Canada

Shipping weight 9 lbs.

REPLACEMENT FACE PANEL

 

Soft white powder coat face panel

Model 4915 

- shipping weight 30 lbs.

FREE-STANDING KIT 

(AC2030T ONLY)

 

Allows single sided furnaces to be surface  

mounted instead of recessed Ideal for  

remodeling in exiting masonry  

construction or when studs are  

substandard. 

(furnace and face  

panel not included.)

 

Model 4901

 - Shipping weight 23 lbs.

250 West Laurel Street · Colton, CA 92324 USA              Subject to change without notice.              © 2021 Williams               L1075  RV 2/21

WARNING:

 This product can expose you to chemicals including epichlorohydrin 

which is known to the State of California to cause cancer and birth defects and/or 

other reproductive harm. For more information go to www.p65warnings.ca.gov

IMPORTANT

FEATURES

11 SV OUTLET  

FOR OPTIONAL  

BLOWER

9 ⅛ʺ

62 ¼ʺ

14 ⅛ʺ MIN.

14 ⅜ʺ MAX

GAS STUB 

LOCATIONS

2ʺ X 4ʺ 

WALL STUDS

16ʺ OC

B/W 4ʺ 

OVAL VENT 

PIPE

2ʺ X 4ʺ 

FLOOR 

PLATE

4 ½ʺ MIN.
5 ⅜ʺ MAX.

VENT

16ʺ

PANEL

AIR FLOW

4 ½ʺ MIN.
5 ⅜ʺ MAX.

PANEL

16ʺ

16ʺ

AIR FLOW

AIR FLOW

TOP-VIEW SINGLE-SIDED MODELS

TOP-VIEW DOUBLE-SIDED MODELS

MODEL DIMENSIONS

WIDTH

DEPTH

HEIGHT

WEIGHT (LBS.)

SINGLE SIDED

FURNACE DIMENSIONS (INCHES)

16

6

65 3/4

106

SHIPPING DIMENSIONS (INCHES)

17 

1/2

11

71

120

DOUBLE SIDED

FURNACE DIMENSIONS (INCHES)

16

6

65 3/4

145

SHIPPING DIMENSIONS (INCHES)

17 1/8

16 3/8

70 7/8

165

MODEL NUMBER

BTU/hr.

INPUT

BTU/hr.

OUTPUT

EFFICIENCY PERCENT

DIGITAL  

THERMOSTAT

(INCLUDED)

POWER

NATURAL

PROPANE

AFUE

SINGLE SIDED

AC2030TN

AC2030TP

30,000

25,428

82%

PROGRAMMABLE

115V-60 HZ, 1 PHASE, 

LESS THAN 5.0 AMPS

DOUBLE SIDED

AC3040TN AC3040TP

40,000

33,272

80%

PROGRAMMABLE

115V-60 HZ, 1 PHASE, 

LESS THAN 5.0 AMPS

 8

.

Set the furnace body into position.  The furnace legs will rest on the bottom base plate panel. Utilizing the  

 

holes provided in the furnace legs, secure the furnace to the brackets attached to the bottom panel with 

 

two (2) #10, 3/4” screws. 

9. 

Install the vent enclosure panel, fastening to side rails with six (6) #6, 3/8” screws.  Trim bottom of panel to fit 

header plate. 

10. Install gas inlet through the back wall or one of the two holes provided in the bottom panel (Figure D).   

 

Connect the gas line to heater in accordance with the installation instructions packed with the furnace and 

 

local codes.     

11.  Install the furnace face panel.  Note that the panel recesses 1/4 inch between the vertical edges of the enclosure 

(refer to you furnace owner’s manual about face panel attachment). 

An Accessory Blower, Model 2901 equipped with an automatic switch will circulate the heat faster.   

Vent

Hold Down Plate 

Header

Furnace

Side Rails 

Base Plate

Shown with vent.  Shown without 

top vent enclosure panel or 

furnace face panel. 

Shown with Accessory Blower Model 2901 or 2907. 

Shown with face panel installed. 

© Williams Furnace Co. 

250 West Laurel Street 

Colton, California 92324 

www.wfc.fc.com 

Subject to change without notice. 

Printed in USA – All Rights Reserved 

P320991, 10/05 

Отзывы: