![Will Burt Night Scan Chief Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/will-burt/night-scan-chief/night-scan-chief_installation-operation-and-maintenance-manual_981734037.webp)
Night Scan Chief
4.4 SYSTEM SCHEMATICS
A system schematic is given in order to aid in electrical troubleshooting as outlined in the following section.
J1
TO HHRC
KA-5
KA-3
WHT
BLK
RED
BLK
A
B
C
D
E
F
G
H
J
K
L
GRN
GRY
VIO
18 GA
20 GA TWISTED PAIRS
BLK
RED
(init)
(kill)
(com)
BATTERY (+) 10 GA
BATTERY (-) 10 GA
TO CUSTOMER
VEHICLE INTERLOCK
(2 AMP. MAX. LOAD)
CLOSED CIRCUIT
WHEN STOWED
SEE SECTION 2.12
BRN
BLU
BLK
WHT
BLK
RED
GRY
VIO
GRN
J4
18 GA
20 GA TWISTED PAIRS
BLU
BRN
4032504 16 FT CABLE
4032505 30 FT CABLE
4032506 50 FT CABLE
BLK
RED
TB3
Figure 4-6 NFPA Handheld Remote Wiring
J1
TO HHRC
WHT
BLK
RED
BLK
A
B
C
D
E
F
G
H
J
K
L
GRN
GRY
VIO
18 GA
20 GA TWISTED PAIRS
BLK
RED
(init)
(kill)
(com)
BATTERY (+) 10 GA
BATTERY (-) 10 GA
BRN
BLU
BLK
WHT
BLK
RED
GRY
VIO
GRN
J4
18 GA
20 GA TWISTED PAIRS
BLU
BRN
4032504 16 FT CABLE
4032505 30 FT CABLE
4032506 50 FT CABLE
BLK
RED
TB3
KA-1
TO CUSTOMER
VEHICLE INTERLOCK
(2 AMP. MAX. LOAD)
CLOSED CIRCUIT
WHEN STOWED
REMOVE G-H JUMPER IF
PARKING BRAKE INTERLOCK
IS USED. CLOSED WHEN
BRAKE "ON"
(SHOWN IN PULLED POSITION)
Figure 4-7 Non-NFPA Hand Held Remote Wiring
Revision 1
4-7