S
TILETTO
AL
O
PERATING
I
NSTRUCTIONS
TP-5418901-F
Original Instructions
8-5
August 2020
8.2.1 Error (Fault) Codes
Table 8-2 shows error (fault) codes that may appear on the Control Box Display. Reoccurrence
of error codes is possible if trigger conditions are met.
Table 8-2 Error (Fault) Codes
Error
Code
Trigger
Condition
System Response
Latch Until
Possible Cause
0001
System voltage
drops below 17
VDC for 5
consecutive
seconds
Excessive Low Volts
Fault (ERR 0001)
:
Disable all normal output
functions. If the
OVERRIDE Switch is
activated while this fault
is active,
re-enable all outputs.
CAUTION:
Avoid unnecessary
attempts to operate the
mast at excessive low
voltage levels to prevent
system damage.
NOTICE:
Even though outputs are
enabled, the mast may
not be able to move due
to the low system
voltage.
•
System is
above 18 volts
and no
Up/Down inputs
are active
- or -
•
System power
is cycled and is
above 18 volts
•
Excessive battery drain
without sufficient charge
current/time
•
Excessive Motor current
due to mast resistance,
excessive payload, or
drive chain binding
•
Insufficient power
supply
•
Too long/undersized
power supply line
(mains)
0002
Control Box
detects 80 Amps
for more than 5
seconds
Excessive Motor
Current Fault
(ERR 0002):
Disable the Motor
Outputs.
•
5 OVERRIDE
Switch
activations
within 3
seconds
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
Excessive Motor current
due to mast resistance,
excessive payload, or
drive system binding
Continued