Warranty 

Will-Burt  warrants  its  Night  Scan  Spot  to  be  free  from  defects  in  material  and 
workmanship for a period of five (5) years with such time periods running from the 
date of shipment by Will-Burt. Will-Burt shall not be responsible for any damage 
resulting  to  or  caused  by  its  products  by  reason  of  failure  to  properly  install, 
maintain or store the product; use of the product in a manner inconsistent with its 
design; unauthorized service, alteration of products, neglect, abuse, accident, or 
acts  of  God.  This  warranty  does  not  extend  to  any  component  parts  not 
manufactured by Will-Burt; provided, however, Will-

Burt’s warranty herein shall not 

limit  any  warranties  by  manufacturers  of  component  parts  which  extend  to  the 
buyer. 

THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, AND 
NO  REPRESENTATIONS,  GUARANTEES  OR  WARRANTIES,  EXPRESS  OR 
IMPLIED,  INCLUDING  BUT  NOT  LIMITED  TO,  A  WARRANTY  OF 
MERCHANTABILITY,  FITNESS  FOR  A  PARTICULAR  PURPOSE,  OR  NON-
INFRINGEMENT  ARE  MADE  BY  WILL-BURT  IN  CONNECTION  WITH  THE 
MANUFACTURE  OR  SALE  OF  ITS  PRODUCTS.  NO  EMPLOYEE, 
DISTRIBUTOR,  OR  REPRESENTATIVE  IS  AUTHORIZED  TO  CHANGE  THIS 
WARRANTY IN ANY WAY OR GRANT ANY OTHER WARRANTY ON BEHALF 
OF WILL-BURT. 

Claims for defects in material and workmanship shall be made in writing to Will-
Burt within thirty (30) days of the discovery of defect. Failure to provide notice as 
required hereby shall be conclusive evidence that the product was in conformity 
with the warranty, and Will-Burt shall be released from any and all liability relating 
to  the  product.  Will-Burt  may  either  send  a  service  representative  or  have  the 
product returned to its factory at Buyer

’s expense for inspection. If judged by Will-

Burt  to  be  defective  in material  or  workmanship, the  product  will  be replaced  or 
repaired  at  the  option  of  Will-Burt,  free  from  all  charges  except  authorized 
transportation. 

THE REMEDIES OF BUYER SET FORTH HEREIN ARE EXCLUSIVE AND ARE 
IN LIEU OF ALL OTHER REMEDIES. THE LIABILITY OF WILL-BURT WHETHER 
IN  CONTRACT,  TORT,  UNDER  ANY  WARRANTY,  OR  OTHERWISE,  SHALL 
NOT EXTEND BEYOND ITS OBLIGATION TO REPAIR OR REPLACE, AT ITS 
OPTION, ANY PRODUCT OR PART FOUND BY WILL-BURT TO BE DEFECTIVE 
IN MATERIAL OR WORKMANSHIP. WILL-BURT SHALL NOT BE LIABLE FOR 
COST  OF  INSTALLATION  AND/OR  REMOVAL,  OR  BE  RESPONSIBLE  FOR 
DIRECT,  INDIRECT,  SPECIAL  OR  CONSEQUENTIAL  DAMAGES  OF  ANY 
NATURE. 

 

 

Содержание 5584901

Страница 1: ...NIGHT SCAN SPOT OPERATOR S MANUAL P N 5584901 The Will Burt Company 401 Collins Boulevard Orrville OH 44667 www willburt com TP 5590101 B October 2019 2019 The Will Burt Company Original Instructions ...

Страница 2: ......

Страница 3: ...ODUCTS NO EMPLOYEE DISTRIBUTOR OR REPRESENTATIVE IS AUTHORIZED TO CHANGE THIS WARRANTY IN ANY WAY OR GRANT ANY OTHER WARRANTY ON BEHALF OF WILL BURT Claims for defects in material and workmanship shall be made in writing to Will Burt within thirty 30 days of the discovery of defect Failure to provide notice as required hereby shall be conclusive evidence that the product was in conformity with the...

Страница 4: ...L ii TP 5590101 B October 2019 Document History Document Numbers Dates Remarks TP 5590101 00 June 17 2019 Initial Release TP 5590101 A July 10 2019 Added Logo TP 5590101 B October 28 2019 Corrected Front Cover and updated Section 2 2 ...

Страница 5: ... Figure 6 1 Battery Compartment 7 Table of Tables Table 1 Night Scan Spot Specifications 2 Table 2 Button Function 5 Safety Summary The Night Scan Spot is engineered and manufactured with safety in mind It is critical that FRC lights are installed maintained and operated correctly Read and understand all instructions before installing performing maintenance or operating All components equipment an...

Страница 6: ...NIGHT SCAN SPOT OPERATOR S MANUAL iv TP 5590101 B October 2019 ...

Страница 7: ... systems customized to meet customer specific needs may vary This manual is for the Night Scan Spot This manual is not for pneumatic Night Scan masts or the electro mechanical Night Scan Lite See www willburt com for information on these and other Will Burt products A typical Night Scan Spot consists of 1 Rotatable Remote Controlled LED Light 2 Wireless Remote Controls 1 1 Safety Precaution Notifi...

Страница 8: ...l Up to 130 ft Approximate Weight 7 lb 3 2 kg Remote Control Battery One 23A battery 12V 1 4 Night Scan Spot Description The Night Scan Spot Figure 1 1 Is a rotatable LED light Is remotely operated with a wireless remote Has a vertical tilt up of 70 and tilt down of 45 Has an infinite horizontal rotational range clockwise and counterclockwise Has 16 LEDs Figure 1 1 Night Scan Spot 9 3 Inches 236 m...

Страница 9: ...turned back on with power restored Section 2 Installation This section describes the installation of the Mast System and provides general procedures that must be followed to ensure a successful installation Use care to understand and follow all precautions while installing 2 1 Installation Safety Precautions Connect the LED light to a 12 or 24 volt DC power source Ensure an appropriate sized circu...

Страница 10: ...re must include proper means to resist vibration loosening such as thread locking compound or locking hardware Torque all hardware as appropriate for its size and grade 6 Move the Remote Control Holder into place in the mounting location 7 Use the Remote Control Holder as a template to drill two holes in the desired mounting location 8 Secure the Remote Control Holder in position using both mounti...

Страница 11: ...on function Warning Signal Press to toggle the Warning Signal on and off When on the light alternates between flashing 3 long flashes and 3 short flashes Up Arrow Press and hold to raise the light beam The light will rotate upward to a maximum of 70 Down Arrow Press and hold to lower the light beam The light will rotate downward to a maximum of 45 Left Arrow Press and hold to pan left Right Arrow ...

Страница 12: ... Remote Control 1 Turn the Night Scan Spot on with the ON OFF button 2 Within 1 minute press and hold the ON OFF button on the Remote Control for 6 seconds Once the Remote Control is paired to the light the light will flash 3 long flashes and then turn off Pairing is complete 3 To pair a second Remote Control repeat steps 1 and 2 4 2 Unpairing Procedure The Remote Control s can unpaired unpaired w...

Страница 13: ...tion and reduce performance of the light Some chemicals will cause the lens to become brittle and prone to cracking Section 6 Battery Replacement To replace the battery in a Remote Control Figure 6 1 1 Turn the Remote Control over to access the back 2 Remove the screw securing the battery cover 3 Remove the battery 4 Replace the battery with 23A 12V battery 5 Replace and secure the battery cover B...

Страница 14: ...NIGHT SCAN SPOT OPERATOR S MANUAL 8 TP 5590101 B October 2019 ...

Отзывы: