WILDLIFE ID1D1F50-E Скачать руководство пользователя страница 2

IOP 005A.5 

Effective Date: 1/06/2017 

Page 2 of 2 

 

 

 

PROCEDURES: 

 

Connect unit to a suitable 110v power supply.  Press 

FWD

 button to

 

start the pump.  Feed rate adjustments 

are performed by pressing the yellow 

UP

 or 

DOWN

 arrow keys while the pump is operating.  This pump is 

used to deliver 5 to 30 L of lampricide per min.  This increases or decreases the RPM of the pump motor 

and the feed rate.  To stop pumping press the red 

STOP

 button. 

 

MAINTENANCE: 

 

Little user-maintenance is required or possible.  Assure that the electronic unit is clean of dust, dirt, and 

moisture. 

 

 

REFERENCE: 

 

“Baldor Series 10 Inverter Control” installation & operating manual. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This procedure has been reviewed and approved by the undersigned representative of the U.S. 

Fish and Wildlife Service. 

 

 

REVIEWED/APPROVED______________________________     DATE____________ 

 

 

 

 

       Field Supervisor (U.S.) 

 

Jessica M. Barber 

Digitally signed by 

JESSICA BARBER 

Date: 2020.03.10 10:37:26 

-04'00'

Отзывы: