background image

IOP 017C.1 

Effective Date: 1/179/2020 

Page 2 of 2

 

 

 

PROCEDURES: 

 

1. 

Connect the AquaPulse to the top of the wading rod. 

 

2. 

Press the 

ON/SELECT

 button to turn unit on. 

 

3. 

Press the 

ON/SELECT 

button to cycle through time intervals until you get to either 100 or 200 

seconds.  

 

  

4. 

Place current meter at desired location in the stream and press “

Count/Stop

” to begin the counting 

process.  The unit will begin counting after the first impulse and the time and revolutions will be 

displayed. 

 

5. 

After at least 40 seconds has elapsed and the number of revolutions reaches one of the numbers on 

the standard rating table (3, 7, 10, 15, 20, etc.), press the 

Count/Stop

 button. The revolution will 

be displayed in the 

Count

 window and the time will be displayed in the 

Time

 window.  Record 

the revolutions and time (rounded to the nearest second) on a discharge measurement form. 

 

6.  

Use the USGS Standard Rating Table 2 to find the velocity.  Record velocity on a discharge 

measurement form. 

 

7. 

Go back to step 3 for next measurement. 

 

 

MAINTENANCE: 

 

Replace battery when needed. 

Wipe with dry soft cloth before storing. 

 

REFERENCES: 

 

 

Rickly Hydrological Co. AquaPulse Impulse Counter/Timer Instruction Manual. 

 

 

This procedure has been reviewed and approved by the undersigned representative of the U.S. 

Fish and Wildlife Service. 

 

 

REVIEWED/APPROVED______________________________     DATE____________ 

 

 

 

 

       Field Supervisor (U.S.) 

 

 

Jessica M. Barber 

Digitally signed by 

JESSICA BARBER 

Date: 2020.03.10 

11:22:55 -04'00'