background image

Setup & Operation 

Unpacking 

Unpack the fixture and carefully inspect for any signs of physical damage. Report any damage to Wildfire or 
your local distributor immediately. Included with each unit should be the following items: 

1.

Twenty clamp, designed to attach the fixture to a 11/2” to 2” pipe truss

2.

Safety Cable, provided to secure the fixture when mounted on a pipe truss

3.

6’ Power Cable

4.

3’ USB Cable

5.

PowerCON 1 Power-Out Connector

6.

Operation Manual and Warranty Registration Card 

Optional Accessories 

Contact Wildfire or your local distributor for pricing on the following optional accessories: 

1. 7.5” and 10” Barn Doors
2. 10° Spot Optic Set
3. 24° Spot Optic Set
4. 40° Spot Optic Set

Installation 

The fixture is equipped with a yoke assembly for mounting. The yoke may be fitted with either a pipe clamp 
(included) for mounting on a pipe truss or a baby bail block or junior pin for mounting on a light stand. 

If the fixture is mounted on a pipe truss, be sure to use the included safety cable, looping it through the yoke 
assembly and around the pipe truss. This will prevent the fixture from falling and possibly causing injury in the 
event that the pipe clamp was not securely tightened. 

To adjust the angle of the fixture, loosen the knobs on either side of the unit slightly, rotate to desired angle and 
tighten. Care should be taken to support the front of the fixture while loosening the knobs to prevent the fixture 
from rotating forward possibly causing injury. 

The fixture comes standard with a 7.5” (VS-60) or 10” (VS-120) bracket assembly for attaching barn doors and 
other accessories. When using accessories, be sure to attach the safety cable provided by the accessory 
manufacturer to the fixture yoke assembly. 

Plug the fixture into the appropriate power source. If you are controlling the fixture with a lighting control board, 
you will need to make sure it is plugged into a non-dim circuit. If the fixture is plugged into a dimmable circuit, it 
will not operate. 

Local Mode Operation 

To operate the fixture in local mode, turn the fixture ON by pushing the power/breaker switch to the ON position. 
Set the Control Source menu selection to “Local.” Set the Dimmer menu selection to the desired output level (0 
– 100%). Set the Effect menu selection to the effect you want.

Effects Settings: 

Setting  

Function 

Description 

OFF 

No Effects 

All LED's static at the brightness set on the Dimmer setting 

Strobe 1-60 

Strobe 

Adjustable strobe of all LED's at the brightness set on the Dimmer setting 

Flash 1-60 

Flash 

Adjustable flash of all LED's at the brightness set on the Dimmer setting 

Pulse 1-60 

Pulse 

Adjustable pulse of all LED's at the brightness set on the Dimmer setting 

Random 1-66 

Random 

Adjustable random strobe of all LED's at the brightness set the Dimmer setting 

Содержание VioStorm Series

Страница 1: ...Operation Manual Ultraviolet LED Lighting Fixtures VS 60 VS 120 TM VIOSTORM English...

Страница 2: ...hical Menu Tree 7 Maintenance 9 Optic Change Replacement 9 Software Updates 9 Cleaning 9 Troubleshooting 9 Diagrams 10 Isometric Line Views VS 60 10 Isometric Line Views VS 120 11 Exploded View VS 60...

Страница 3: ...unit s warranty Safety Information RISK GROUP 3 WARNING THIS FIXTURE EMITS ULTRAVIOLET RADIATION UV AT A PRIMARY WAVELENGTH OF 365NM AVOID EYE AND SKIN EXPOSURE AT DISTANCES SHORTER THAN 3 3 1m DO NOT...

Страница 4: ...owerCON 1 Input and Output Power Linking VS 60 Eight units at 120VAC VS 120 Four units at 120VAC Power Cord 9 14 3 SOW with PowerCON 1 and male Edison DMX Connections Neutrikl Gold 5 pin XLR Male 5 pi...

Страница 5: ...to desired angle and tighten Care should be taken to support the front of the fixture while loosening the knobs to prevent the fixture from rotating forward possibly causing injury The fixture comes...

Страница 6: ...m Strobe of all LED s at the output set on the dimmer channels RDM Remote Device Management is a protocol enhancement to DMX512 that allows bidirectional communication between a system controller and...

Страница 7: ...DMX Address 510 Pressing UP or DOWN adjusts this selection when Control Source is set to Local Pressing UP or DOWN has no function when Control Source is set to DMX Dimmer Local 7 Effects Selections a...

Страница 8: ...on is complete it will return to the home menu and resume normal operation Program Update Confirm UP Returns to Home Menu Graphical Menu Tree Device ID 0X57466E228870 SELECT Pressing UP or DOWN has no...

Страница 9: ...provided to update the software Fig 1 Cleaning For best performance the fixture fan vents should be kept free of dirt and dust At no time should any cleaning chemicals or abrasives be used to clean an...

Страница 10: ...Isometric Line Views VS 60 10 Diagrams 901 113 03 VS 60 Line 11 31 7 50 14 54 7 56 8 96 16 97 17 34 9 33 10 24...

Страница 11: ...Isometric Line Views VS 120 11 Diagrams 901 114 01 VS 60 Line 13 81 10 00 17 51 15 12 7 81 11 23 11 43 11 80 17 89...

Страница 12: ...ded View VS 60 12 900 113 03 VS 60 Exploded 31 35 46 23 47 22 51 39 40 19 38 41 10 36 33 23 12 8 13 9 1 11 47 29 30 27 28 45 16 47 4 47 5 2 44 6 7 22 34 21 23 3 42 47 24 26 14 15 43 20 25 18 17 37 48...

Страница 13: ...er Black 16 AWG 8ft 25 2 120 004 Knob Floor Stand Bracket 26 1 106 050 Connector PowerCON 1 Power IN QTY PART PART NAME 27 1 104 077 03 Base Accessory Safety Catch 28 1 104 078 02 Latch Accessory Safe...

Страница 14: ...ed View VS 120 14 900 114 02 VS 120 Exploded 13 7 1 3 9 5 4 47 34 37 39 36 10 35 38 33 32 11 17 18 27 16 12 12 26 25 19 15 12 20 22 23 21 31 28 29 50 49 51 41 42 48 43 46 44 45 2 11 6 14 12 10 8 10 24...

Страница 15: ...02 Circuit Breaker Carling 5A 25 1 104 113 01 Cover Housing Rear VS 120 26 1 106 060 Connector Mini B USB Female QTY PART PART NAME 27 4 121 071 Standoff 3 16 Hex THD F F 2 56 x 7 16 28 1 106 050 Conn...

Страница 16: ...C POWER SUPPLY 48VDC OUTPUT POWER SWITCH CIRCUIT BREAKER AC OUTPUT AC INPUT DMX CONTROL BOARD FAN A P T FAN B P T FAN C P T USB DMX DMX CH 3 CH 2 CH 1 CH 4 LED DRIVER BOARD THERMISTOR 48VDC INPUT 48VD...

Страница 17: ...R SUPPLY 48VDC OUTPUT DMX CONTROL BOARD FAN A P T FAN B P T FAN C P T USB DMX DMX CH 3 CH 2 CH 1 CH 4 LED DRIVER BOARD THERMISTOR 48VDC INPUT 48VDC INPUT LED MODULE 2 LED MODULE 1 CAPACITIVE TOUCH CON...

Страница 18: ...8 30 11 67 3 1 42 50 12 95 2 4 Model VS 60F 40 Flood Distance in Feet Meters 3 60 1 10 650 7 30 2 22 162 5 14 60 4 45 40 6 21 80 6 64 18 0 29 10 8 87 10 1 36 40 11 09 6 5 43 70 13 32 4 5 51 00 15 54 3...

Страница 19: ...38 30 11 67 4 7 42 50 12 95 3 8 Model VS 120F 40 Flood Distance in Feet Meters 3 60 1 10 1325 7 30 2 22 331 14 60 4 45 82 8 21 80 6 64 36 8 29 10 8 87 20 7 36 40 11 09 13 2 43 70 13 32 9 2 51 00 15 5...

Страница 20: ...od is to notify Wildfire of any suspected defect to obtain a return authorization number and to return the product freight and insurance prepaid to the following address Wildfire Service 2908 Oregon C...

Страница 21: ...800 937 8065 Fax 310 755 6781 www wildfirefx com mail wildfirefx com Wildfire and its symbol are registered trademarks of Wildfire Inc Torrance CA Ignite Your Imagination is a registered trademark of...

Страница 22: ...Manuel d op ration Luminaires DEL ultraviolette VS 60 VS 120 TM VIOSTORM Fran ais...

Страница 23: ...7 Entretien 9 Changement Remplacement des l ments optiques 9 Mises jour du logiciel 9 Nettoyage 9 D pannage 9 Diagrammes 10 Vues isom triques et des lignes VS 60 10 Vues isom triques et des lignes VS...

Страница 24: ...ISQUES 3 AVERTISSEMENT CE LUMINAIRE MET UNE RADIATION ULTRAVIOLETTE UV UNE LONGUEUR D ONDE PREMI RE DE 365 NM VITEZ L EXPOSITION VISUELLE ET CUTAN E DES DISTANCES PLUS COURTES QUE 1 M 3 3 PI NE REGARD...

Страница 25: ...es Entr e et sortie Neutrik PowerCON 1 Raccordement lectrique VS 60 Huit unit s 120VAC VS 120 Quatre unit s 120VAC Cordon d alimentation SOW de 2 7 m 9 pi 14 3 avec PowerCON 1 et Edison m le Connexion...

Страница 26: ...reil tourner l angle d sir et serrer Des soins doivent tre pris pour soutenir l avant du luminaire lorsque vous desserrez les boutons pour emp cher le luminaire de tourner vers l avant causant possibl...

Страница 27: ...e toutes les DEL la sortie r gl e sur les canaux de l affaiblissement RDM La gestion des appareils distance RDM est une am lioration de protocole au DMX512 qui permet une communication bidirectionnell...

Страница 28: ...ppuyer sur HAUT ou BAS r gle ce choix lorsque la source de contr le est r gl e local Appuyer sur HAUT ou BAS n a aucune fonction lorsque la source de contr le est r gl e DMX Gradateur Local 7 Les choi...

Страница 29: ...menu d accueil et poursuivra l op ration normale Mise jour du programme Confirmer UP Retour au Menu d accueil Arbre du menu ID du dispositif 0X57466E228870 SELECT Appuyer sur HAUT ou BAS n a aucune fo...

Страница 30: ...structions fournies pour mettre jour le logiciel Fig 1 Nettoyage Pour une meilleure performance les vents du ventilateur du luminaire doivent tre maintenus exempts de salet s et de poussi re En aucun...

Страница 31: ...Vues isom triques et des lignes VS 60 10 Diagram Ligne 901 113 03 VS 60 11 31 7 50 14 54 7 56 8 96 16 97 17 34 9 33 10 24...

Страница 32: ...Vues isom triques et des lignes VS 120 11 Diagram Ligne 901 114 01 VS 60 13 81 10 00 17 51 15 12 7 81 11 23 11 43 11 80 17 89...

Страница 33: ...lat e VS 60 12 Vue clat e 900 113 03 VS 60 31 35 46 23 47 22 51 39 40 19 38 41 10 36 33 23 12 8 13 9 1 11 47 29 30 27 28 45 16 47 4 47 5 2 44 6 7 22 34 21 23 3 42 47 24 26 14 15 43 20 25 18 17 37 48 4...

Страница 34: ...4 m 8 pi 25 2 120 004 Bouton support de plancher 26 1 106 050 Connecteur PowerCON 1 entr e de l alimentation QTE NUM RO PI CE NOM DE LA PI CE 27 1 104 077 03 Base accessoire loquet de s curit 28 1 104...

Страница 35: ...at e VS 120 14 Vue clat e 900 114 02 VS 120 13 7 1 3 9 5 4 47 34 37 39 36 10 35 38 33 32 11 17 18 27 16 12 12 26 25 19 15 12 20 22 23 21 31 28 29 50 49 51 41 42 48 43 46 44 45 2 11 6 14 12 10 8 10 24...

Страница 36: ...113 01 B ti du couvercle arri re VS 12 26 1 106 060 Connecteur Mini B USB femelle QTE NUM RO PI CE NOM DE LA PI CE 27 4 121 071 Entretoise hex 4 7 mm 3 16 po THD F F 2 56 x 11 1 mm 7 16 po 28 1 106 0...

Страница 37: ...PTEUR D ALIMENTATION DISJONCTEUR SORTIE CA ENTR E CA PANNEAU DE CONTR LE DMX VENTILATEUR A P T VENTILATEUR B P T VENTILATEUR C P T USB DMX DMX CH 3 CH 2 CH 1 CH 4 PANNEAU DU CONTR LEUR DES DEL THERMIS...

Страница 38: ...NTR LE DMX VENTILATEUR A P T VENTILATEUR B P T VENTILATEUR C P T USB DMX DMX CH 3 CH 2 CH 1 CH 4 PANNEAU DU CONTR LEUR DES DEL THERMISTANCE ENTR E 48 VCC ENTR E 48 VCC MODULE DEL 2 MODULE DEL 1 INTERR...

Страница 39: ...0F r flecteur 40 Distance en pieds m tres 3 60 1 10 650 7 30 2 22 162 5 14 60 4 45 40 6 21 80 6 64 18 0 29 10 8 87 10 1 36 40 11 09 6 5 43 70 13 32 4 5 51 00 15 54 3 3 58 20 17 74 2 5 Diam tre du fais...

Страница 40: ...120F r flecteur 40 Distance en pieds m tres 3 60 1 10 1325 7 30 2 22 331 14 60 4 45 82 8 21 80 6 64 36 8 29 10 8 87 20 7 36 40 11 09 13 2 43 70 13 32 9 2 51 00 15 54 6 7 58 20 17 74 5 1 Diam tre du f...

Страница 41: ...ts ou de revenus ou pour tout autre frais L obligation du propri taire lors de la p riode de garantie est d aviser Wild re de toute d faillance possible d obtenir un num ro d autorisation de retour et...

Страница 42: ...l copieur 310 755 6781 www wildfirefx com mail wildfirefx com Wildfire et son symbole sont des marques de commerce d pos es de Wildfire Inc Torrance CA Ignite Your Imagination est une marque de commer...

Отзывы: