Maintenance & Troubleshooting 

 
 

Lamp Replacement 

Unplug the fixture. Remove any accessories from the front. Set the focus control to the F position Make sure the 
fixture is cool to the touch before opening the lens door. Release the lens door latch by pulling the latch away 
from the door. Swing the front lens door open. Grasp the lamp in the center remove it by pushing it gently to one 
side sliding the other end forward. Reverse this procedure to install the new lamp. After installing gently rock the 
new lamp back and forth to insure the depressions on the ends of the lamp are firmly seated on the posts of the 
sockets. If the lamp is not firmly seated arcing could occur melting both the socket and lamp. Care should be 
taken not to touch the new lamp directly use a cloth or glove when handling if you have touched the lamp it must 
be cleaned with alcohol to remove any oils and fingerprints prior to striking. For maximum UV-A output always 
use Wildfire IronArc

®

 lamps, and change the lamp in your fixture every 1000 hours. 

 

Cleaning 

For best performance, the reflector, lamp and filter lens should be kept free of dirt and dust.  At no time should 
any cleaning chemicals or abrasives be used to clean any part of the fixture. Do not spray or apply any liquid 
directly to any part of the fixture.  Always unplug the unit. before cleaning. For normal cleaning, a dry soft cloth 
should be used to wipe any surface free from dust and light dirt.  Cleaning the reflector will require that the lamp 
be removed.  Remove the lamp by following the instructions listed under lamp replacement above. Once the 
lamp has been removed, gently wipe off the reflector using a soft dry cloth. In the event the reflector is heavily 
soiled, lightly dampen the cloth with a mild window cleaning agent and wipe clean. The filter lens can be cleaned 
in the same manner. The lamp should be cleaned with alcohol only. 
 

Troubleshooting 

 

Red LED is flashing display reads 1000 to 9999: -- 

The lamp has reached the end of its life, reducing UV 

output considerably. Replace the lamp in the fixture. 
 

Red LED is on and the display is flashing “O F F”:

 -- The fixture is attempting to strike the lamp however the 

lamp has either not cooled enough to strike or the lamp is bad. Wait 5 minutes for the lamp to completely cool. If 
it still won’t strike, replace the lamp. 
 

Green LED is flashing and the display reads “0 0 0”:

 -- The fixture is set for a valid DMX address however 

DMX signal is not being received. Check DMX settings on control board or software as well as cabling to the 
fixture. 
 

Display and LED’s are not lit:

 -- Fixture is operating in dark mode, press the select button to reactivate the 

display and LED’s. 
 

The fixture will not strike:

 – Check to make sure there is power to the ballast. Make sure the power/breaker 

switch on the ballast has not been tripped. Unplug the ballast. Check to see if the fixture has a lamp installed 
and that it is seated properly in the sockets (see lamp replacement above). Check to see if the safety cutoff 
switch is making contact by closing the lens cover and listening for a clicking sound. If the fixture still is not 
striking try replacing the lamp. If you have checked all of the above and the fixture still won’t strike contact 
Wildfire technical support at (310) 645-7787 or your local distributor. 
 

The effect is not working anymore:

 – Try changing the lamp. The lamp in your Wildfire fixture is rated at 1000 

hours. This does not necessarily mean that the lamp will “burn out” or not light after 1000 hours it may continue 
to burn for a much longer period of time however the amount of UV it produces will be reduced considerably 
causing the effect to appear as though it isn’t working. Wildfire recommends for maximum effect to change the 
lamp every 1000 hours. 
 
 
 
 
 

Содержание LT-404S/F1 Kit

Страница 1: ...LT 404S FF Kit LT 404S FG Kit LT 404S FH Kit LT 404S FI Kit LT 404S F1 Kit LT 404S F2 Kit...

Страница 2: ...placement 7 Cleaning 7 Troubleshooting 7 Diagrams 8 Isometric Line Views Lamp Assembly 8 Isometric Line Views Ballast 9 Exploded View Lamp Assembly 10 Part List Lamp Assembly 11 Exploded View Ballast...

Страница 3: ...O ULTRAVIOLET UV RADIATION DO NOT OPERATE WITHOUT COMPLETE LAMP ENCLOSURE IN PLACE OR IF FILTER GLASS LENS IS DAMAGED DANGER INTENSE HEAT AVOID CONTACT BY PERSONS AND MATERIAL CAUTION RISK OF ELECTRIC...

Страница 4: ...Wildfire IronArc 400 Watt Metal Halide Model LMP 400D 1000 Hr Rated Beam Adjustable 8 to 59 Reflector Alzak Coated Aluminum Lens 8 UV A Transmitting Fresnel Filter Glass Peak Spectral Transmission 35...

Страница 5: ...hen using accessories with this fixture be sure to attach the safety cable provided by the accessory manufacturer to the fixtures yoke assembly Connect the lamp assembly to the ballast using the inclu...

Страница 6: ...powered up and the lamp doesn t ignite the display will flash O F F while in this mode until the lamp ignites If another mode is selected at this time the display will always default back to the Lamp...

Страница 7: ...t and wipe clean The filter lens can be cleaned in the same manner The lamp should be cleaned with alcohol only Troubleshooting Red LED is flashing display reads 1000 to 9999 The lamp has reached the...

Страница 8: ...Isometric Line Views Lamp Assembly 8 Diagrams 13 44 12 75 10 75 10 00 14 25 18 86 21 84...

Страница 9: ...Isometric Line View Ballast 9 9 25 9 25 18 87 12 74 14 37 9 25 10 61...

Страница 10: ...23 2 26 46 24 27 11 13 28 53 32 48 44 22 54 59 58 56 55 57 68 45 51 47 50 34 8 29 6 36 39 5 33 9 51 33 31 34 8 6 29 20 36 60 62 61 26 4 7 3 24 35 10 1 11 43 63 64 30 12 37 12 41 67 65 66 42 40 19 52 4...

Страница 11: ...SS Tooth Washer 29 4 MFG 0048 Nut 4 40 18 8 SS w Tooth Washer 30 1 MFG 0051 Nut Blind Rivet 8 32 31 1 MFG 0053 Bracket Keystone 32 2 MFG 0062 MS PH PHL 10 32 1 75 18 8 SS 33 3 MFG 0078 MS PH PHL 6 32...

Страница 12: ...Exploded View Ballast LT 404S F F G H I 12 4 42 41 19 15 26 27 28 29 3 12 33 30 34 25 2 27 14 32 23 1 5 35 11 31 36 7 8 6 37 20 18 24 13 21 12 17 16 22 14 32 Optional Outdoor Kit 38 39 40 9 10...

Страница 13: ...itor Oil 20 2 HAR 0050 Knob Yoke Adjustment 21 1 HAR 2000 Cable Safety 1 8 QTY PART PART NAME 22 1 HSG 400B Housing Ballast 23 1 LAB 0005 Control Label WF 404B 24 2 MFG 0001 Nut Blind Rivet 3 8 16 25...

Страница 14: ...Exploded View Ballast LT 404S F 1 2 14 4 3 12 23 2 24 14 28 21 1 5 29 11 27 30 7 8 6 31 18 17 22 13 19 12 16 15 20 14 28 Optional Outdoor Kit 9 10 32 33 26 25...

Страница 15: ...5 8 GKT 0002 Gasket Lens Door 401 600 16 1 HAR 0019 Pipe Clamp Mega Claw 17 2 HAR 0020 Spacer Casting Yoke QTY PART PART NAME 18 2 HAR 0050 Knob Yoke Adjustment 19 1 HAR 2000 Cable Safety 1 8 20 1 HSG...

Страница 16: ...D SELECT DOWN UP MEMBRANE SWITCH B C D E F G A LAMP ASSEMBLY CONNECTION CAPACITOR 120V 208V 240V 277V COM COM 120 277VAC 60Hz PS MH400IK Ballast 120V 220 240V 120 240VAC 50Hz PS MH400HJ Ballast 100V 2...

Страница 17: ...ER SUPPLY BOARD DMX IN DMX OUT G G AC INPUT AC OUTPUT CONTROL FAN DMX CONTROL BOARD SELECT DOWN UP MEMBRANE SWITCH 400W ELECTRONIC BALLAST G N L LAMP GROUND B C D E F G A LAMP ASSEMBLY CONNECTION B C...

Страница 18: ...8 2 9 7 0 2 1 3 3 8 0 2 4 3 8 9 0 2 7 4 3 1 0 0 3 0 4 8 1 1 0 3 3 5 3 1 2 0 3 6 5 7 1 3 0 3 9 4 2 1 40 0 43 879 9 2 80 0 85 220 9 4 20 1 28 101 5 60 1 71 56 4 7 00 2 13 39 9 8 40 2 56 23 5 9 80 2 99...

Страница 19: ...l wildfirefx com Wildfire and its symbol are registered trademarks of Wildfire Inc Los Angeles CA IronArc and its symbol are registered trademarks of Wildfire Inc Los Angeles CA The Professional Choic...

Отзывы: