P E R F O R M A N C E
PX1500
Performance
25
WILDEN PUMP & ENGINEERING, LLC
SET
TING 4 PERFORMANCE CUR
VE
EMS CUR
VE
PX1
50
0 DROP
-IN S
T
AINLESS S
TEEL FULL S
TROKE PTFE-FITTED
EXAMPLE
A PX1500 stainless steel, Full Flow PTFE fi
tted pump operating at EMS
setting 4, achieved a fl
ow rate of 454 lpm (120 gpm) using 155 Nm
3
/h
(91 scfm) of air when run at 4.7 bar (68 psig) air inlet pressure and 2.8
bar (40 psig) discharge pressure (See dot on performance curve).The
end user did not require that much fl
ow and wanted to reduce air
consumption at his facility
. He determined that EMS setting 2 would
meet his needs. At 2.8 bar (40 psig) discharge pressure and EMS
setting 2, the fl
ow “X factor” is 0.75 and the air “X factor” is 0.66 (see
dots on EMS curve).
Multiplying the original setting 4 values by the “X factors” provides
the setting 2 fl
ow rate of 341 lpm (90 gpm) and an air consumption
of 102 Nm
3
/h (60 scfm). The fl
ow rate was reduced by 25% while
the air consumption was reduced by 34%, thus providing increased
effi
ciency
.
For a detailed example for how to set your EMS, see beginning of
performance curve section.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
The Effi
ciency Management System (EMS)
can be used to optimize the performance of
your Wilden pump for specifi
c applications.
The pump is delivered with the EMS adjusted
to setting 4, which allows maximum fl
ow
.
The EMS curve allows the pump user to deter
-
mine fl
ow and air consumption at each EMS
setting. For any EMS setting and discharge
pressure, the “X factor” is used as a multi-
plier with the original values from the setting
4 performance curve to calculate the actual
fl ow and air consumption values for that spe-
cifi
c EMS setting. Note: you can interpolate
between the setting curves for operation at
intermediate EMS settings.
TECHNIC
AL D
A
T
A
Height
. . . . . . . . . . . . . . . . . . . . . . . . . .
815 mm (32.1”)
Width
. . . . . . . . . . . . . . . . . . . . . . . . . . .
650 mm (25.6”)
Depth
. . . . . . . . . . . . . . . . . . . . . . . . . . .
422 mm (16.6”)
Ship W
eight
. . . . . . . . . . . . . . . . . . . .
126 kg (278 lbs.)
Air Inlet
. . . . . . . . . . . . . . . . . . . . . . . . . .
19 mm (3/4”)
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76 mm (3”)
Outlet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76 mm (3”)
Suction Lift
. . . . . . . . . . . . . . . . . . . . .
6.1m Dry (19.9’)
9.3 m W
et (30.6’)
Disp. Per Stroke
. . . . . . . . . . . . . . . . .
5.2 l (1.38 gal.)
1
Max. Flow Rate
. . . . . . . . . . . . .
985 lpm (260.1 gpm)
Max. Size Solids
. . . . . . . . . . . . . . . . .
12.7 mm (1/2”)
1
Displacement per stroke was calculated at 4.8 bar (70 psig)
air inlet pressure against a 2.1 bar (30 psig) head pressure.
Содержание PX1500 Advanced Series
Страница 9: ...PX1500 M E T A L P X 1 5 0 0 P E R F O R M A N C E...
Страница 31: ...N O T E S...
Страница 45: ...N O T E S...
Страница 49: ...N O T E S...