![Wilden P4 series Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/wilden/p4-series/p4-series_operation-and-maintenance-manual_980878015.webp)
WIL-10183-E-04
15
P4 Clamped Metal
SECTION 7
PUMP DISASSEMBLY
Tools Required:
7/16" Wrench
1/2" Wrench
Adjustable Wrench
Vise equipped with soft jaws
(such as plywood, plastic or other
suitable material)
CAUTION:
Before attempting any maintenance or repair, disconnect the compressed
air line to the pump and allow all air pressure to bleed from the pump. Disconnect all
intake, discharge, and air lines. Drain the pump by turning it upside down and allowing
any fluid to flow into a suitable container. Be aware of any hazardous effects of contact
with your process fluid.
NOTE:
Your specific pump model may vary from the configuration shown; however,
pump disassembly procedure will be the same.
NOTE:
Replace worn parts with genuine Wilden parts for reliable performance.
Step 1
Step 2
Step 3
Before starting disassembly, mark a line
from each liquid chamber to its
corresponding air chamber. This line will
assist in proper alignment during
reassembly.
Using
a
7
⁄
16" wrench, remove the two (2)
small clamp bands that fasten the
discharge manifold to the liquid chambers.
Remove the discharge manifold to expose
the valve balls and seats. Inspect ball cage
area of manifold for excessive wear or
damage.
DISASSEMBLY / REASSEMBLY
Содержание P4 series