P-Maintenance

Brew By Time

Brew By Volume

Displ. Brew Time

Pre-infusion

Pulse Brew

P-Maintenance (Factory set to OFF)

Press 

 to select, set gallons brewed to indicate P-Maintenance. Press  < or > to adjust from Off to 9500 gallons. This 

feature advances in 500 gallon increments. Press 

 to exit.

Beeper On/Off (Factory set to ON)

Press 

 to display ON or OFF. Pressing either < or > toggles between on and off. 

 to set. When ON, this feature allows 

you to hear a short beep each time a button is pressed.

Drip-out Mode (Factory set to 2 minutes) 

Press 

 to select. Press < or >  to move to desired time. Settings are OFF, 1, 2, 3, 4 and 5 minutes. Press 

 to select 

time.

Warmers Default (Factory setting - MED)

Press 

 to select. Press  < or > to adjust from OFF, HIGH (100 Watts), MED (82 Watts) or LOW (66 Watts). 

Displ. Brew Time (Factory set to ON)

Press 

 to display ON or OFF. Pressing either < or > toggles between on and off. After Display Brew Time an EXIT screen 

will return you to Non‑Brew Prog.

Display Messages (Factory set to ON) 

Display Messages allows the operator to change the screen display to read “Rinse Server Before Brewing” or to turn it off.

Press 

 to display ON or OFF. Pressing either < or > toggles between on and off. 

 to set. 

Display Timers (Factory set to OFF)

Press 

 to display ON or OFF. Pressing either < or > toggles between on and off. This feature allows the operator to turn 

off or on the display for the quality timer count-down. At the same time, it also turns off or on the audible alarm. Press 

 to 

set and exit.

QT Alarm On/Off (Factory set to ON)

Press 

 to display. Pressing < or > toggles between on and off. This feature is an audible alarm that sounds when time has 

expired. Press 

 to set and exit. Functions only when quality timer is enabled.

Drip-out Mode

Beeper On/Off

Warmers Default

BREW BUTTON PROGRAMMING

Brew by Volume (Factory settings: LARGE 200oz ±8oz. MEDIUM 132oz±6oz. SMALL 64oz±4oz.)

Press 

 to select. Display will ask you to select a brew button, Large, Medium or Small. Press the desired brew button to 

begin... when desired volume is reached press the same brew button to stop the flow. Now the volume has been set. 

Brew by Time (Factory settings: LARGE 5min-25sec. MEDIUM 3min-32sec. SMALL 1min-52sec.) 

Next item in the sequence is Brew by Time. Press 

 to select to change the brew time. Display will now show the current 

time. By pressing < or > you can toggle back and forth from minutes to seconds to exit (ex). Change the time or set and exit 

by pressing the 

 button. 

Pre-Infusion (Factory Disabled)

Press 

 to select. Current setting in seconds is displayed  < to decrease or select  >  to increase (range from OFF to 10 

through 60 seconds), 

 to set. 

If Pre-infusion is selected (ON), Cold Brew Lock is set within 5ºF of set point and Cold Brew Lock disappears from the list of 

program selections. When Pre‑infusion  is ON, Pulse Brew disappears from the list of program selections. 

Pulse Brew (Factory set to Pulse C). 
Press 

 to select, < or > to select OFF or one of five pulse patterns (A to E) . The five Pulse Brew options help “tune” or 

change the coffee flavor.
Guidelines for Pulse Brew:
A pulse setting: 10 sec ON 4 times. 10 sec OFF 4 times. Afterwards, ON until the end of the brew cycle. 
B pulse setting: 60 sec ON, then 10 sec OFF 4 times. 10 sec ON 4 times. Afterwards, ON until the end of the brew cycle.
C pulse setting: 25 sec ON 5 times, then 20 sec OFF 5 times. Afterwards, ON until the end of the brew cycle.
D and E are manual pulse counts. 

Display Messages

Display Timers

QT Alarm On/Off

Program Menus GEMSS Brewer

Содержание GEM SS

Страница 1: ...ase use this setup procedure before attempting to use this brewer Failure to follow the instructions can result in injury or the voiding of the warranty WARNING TO AVOID SCALDING Do not remove brew co...

Страница 2: ...ly 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen It takes approximately 20 minutes to reach set point temperature of 200 F Control will display wh...

Страница 3: ...CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first setting is within 5 degrees of set point next is w...

Страница 4: ...expired Press to set and exit Functions only when quality timer is enabled Drip out Mode Beeper On Off Warmers Default BREW BUTTON PROGRAMMING Brew by Volume Factory settings LARGE 200oz 8oz MEDIUM 13...

Страница 5: ...to the defaults of the newly selected model Also the next feature Batch Select appears Batch Select Factory set to One Batch Press to select or to select One Batch Two Batch or Three Batch Press to s...

Страница 6: ...4 ADJUST 3 8 16 THREAD PART ITEM DESCRIPTION 16 17 18 18A 19 20 21 22 22A 23 24 24A 25 26 27 28 28A 29 30 31 32 WC 5451 WC 43089 WC 37102 WC 975 WC 3765L WC 37132 WC 2977 101K WC 37176 WC 723 WC 5853...

Страница 7: ...7 Electrical Schematic GEM SS...

Страница 8: ...SHIELD BASE 3 16 FAUCET S NON LOCKING KIT FAUCET S SERIES KIT SHANK ASSY FAUCET W SHIELD BASE O RING SHANK FAUCET W SHIELD BASE OLDER UNITS KIT WARMER ELEMENT 100W 120V LEG SCREW BUMPER 3 8 16 STD SW...

Страница 9: ...ean the Satellite components prepare a mild solution of detergent and warm water DO NOT immerse the satellite in water or any other liquid 1 Remove lid from satellite Clean the lid at the funnel area...

Страница 10: ...plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessi...

Отзывы: