background image

POSSIBLE CAUSE

SOLUTION

TROUBLE SHOOTING

Open the water line and make sure water flows to the brewer.

Turn off brewer. Disconnect wires from water inlet coil terminals
and connect a power cord to the terminals. Plug cord into a 110v
outlet and verify that water flow when plugged in and stops when
cord is disconnected. If valve does not respond to this test, replace
the valve.

When water in the heating tank is below the probe tip, yet water is
not refilling, pull the wire off the probe terminal. If water starts flowing
into the tank, find ground, clean or replace the probe.

Pull the wire from the probe terminal. With a volt meter, check the
voltage at the water inlet coil terminals. This should read 110 to 115
volts. If no voltage is present, check the water level control board.
Make sure that the back of the board is grounded securely to the
mounting bracket. Check for loose wire connections. Replace
board.

1. Water line turned off or

filter clogged up.

2. Water inlet valve coil

burned out

3. Grounded probe (item

#12)

4. Defective or burned out

water level control board
(item #3)

PROBLEM: 

WATER IN TANK DOES NOT GET HOT OR WATER TEMPERATURE TOO LOW

POSSIBLE CAUSE

SOLUTION

8. Thermostat is off (item #31) Check the thermostat (item #31) to make sure it is in the ON posi-

tion. Turn the thermostat stem clockwise until it stops.

9. Burned out heating
    element.

Check element for continuity and/or check with clamp ammeter. This
should show a reading of approximately 15 amps. If no power is
going through element, replace it.

PROBLEM: 

WATER DOES NOT FLOW INTO HEATING TANK

POSSIBLE CAUSE

SOLUTION

Turn power off and observe the water level in the heating tank. If
water continues to flow in, clean or replace the valve.

Pull wire off from probe terminal. Touch the water tank shell with the
terminal at the end of this wire. If water stops flowing, clean or
replace the probe.

If probe is okay, check the water level control board. The water level
control board must be securely grounded. Check for loose connec-
tions. Check for voltage at the inlet valve terminals. Replace board.

5. Defective water inlet

valve (item #28)

6. Probe limed up (item #12)

7. Loose or ungrounded

water level control board
(item #3)

PROBLEM: 

WATER IN HEATING TANK OVERFLOWING

- 3 -

GEMINI 120A

Содержание CA 90640

Страница 1: ...12345678901 12345678901234567890123456789012123456789012345678901 12345678901234567890123456789012123456789012345678901 12345678901234567890123456789012123456789012345678901 12345678901234567890123456...

Страница 2: ...INSIDE FRONT COVER IS A BLANK PAGE...

Страница 3: ...ect the water line to the inlet valve fitting and turn on the water 4 With the top cover removed turn thermostat stem clockwise until it stops 5 Plug the unit into a power supply outlet and turn toggl...

Страница 4: ...ont panel the brew selector switch should be at 2 This setting will deliver one gallon of water brew 24 cups per brew cycle To brew 12 cups simply turn the brew selector knob to 1 If finer adjustments...

Страница 5: ...2 4 Defective or burned out water level control board item 3 PROBLEM WATER IN TANK DOES NOT GET HOT OR WATER TEMPERATURE TOO LOW POSSIBLE CAUSE SOLUTION 8 Thermostat is off item 31 Check the thermosta...

Страница 6: ...volts across terminals 6 and A of the timer The RED wire on terminal 6 supplies power to open the dump valve If no voltage is present replace the timer If the timer works when the brew switch is press...

Страница 7: ...ART PART PART N N N N N INDEX INDEX INDEX INDEX INDEX N N N N N 9 10 11 11A 12 13 14 15 WC 2007 WC 1901 WC 1800 WC 1841 WC 3705 GEM4 WC 3503 WC 37102 BRACKET GAUGE GLASS FORMED SHANK FAUCET D T CHROME...

Страница 8: ...6 GEMINI 120A Parts List B 8 2 7 2 8 B 2 5 6 3 1 6 1 4 2 1 1 4 1 9 2 0 2 4 5 7 13 1 3 9 1 0 1 1 1 2 1 7 1 5 1 5 1 8 1 8 2 3 2 2 2 6 2 9 3 0 5 23 00 8 9 f 1903 p65 p8X 3 1...

Страница 9: ...OGGLE SPST 25A 125 250 VAC RESISTIVE LEG SCREW BUMPER 3 8 16 STD KIT BREW CONE W BASKET SS 7 1 8 DELUXE BLK HANDLE OPTIONAL COVER FRONT GEM 120A 120P 230A 200R 300IL 600ILD COVER TOP D500 G230A G120A...

Страница 10: ...8 WIRING DIAGRAM GEM120A 10 VOLTAGE 120VAC 1775 15 60 2 GND 1 WATTAGE AMPERAGE WIRES HERTZ PHASE...

Страница 11: ...9 WIRING DIAGRAM GEM120A 63 VOLTAGE 120 220VAC 1775 2100 15 10 60 3 GND 1 WATTAGE AMPERAGE WIRES HERTZ PHASE...

Страница 12: ...nal certified technician and must comply with all local electrical mechanical and plumbing codes 3 Wilbur Curtis Company will not be responsible for the operation of equipment at other than the stated...

Отзывы: