EN
14170746.05 03/2022 EN/DE/FR/ES
WIKA additional information model TR21 (Ex i)
11
■
Thermometer with direct sensor output with Pt100 (model TR21-x-xPx) and
Pt1000 (model TR21-x-xRx)
Parameters
Hazardous gas
atmosphere
Hazardous dust
atmosphere
Terminals
1 - 4
1 - 4
Voltage U
i
DC 30 V
DC 30 V
Current l
i
550 mA
250 mA
Power P
i
1,500 mW
750/650/550 mW
Effective internal capacitance C
i
negligible
negligible
Effective internal inductance L
i
negligible
negligible
Maximum self-heating at the
sensor or thermowell tip
(R
th
) = 335 K/W
(R
th
) = 335 K/W
3.5 Overview of the temperature zones
■
Model TR21-A
14103751.02
with transmitter
without transmitter
T
a
: -40 ... +85 °C
T
a
: -50 ... +85 °C
T
a
: -40 ... +100 °C
T
a
: -50 ... +100 °C
T
a
: -40 ... +150 °C
T
a
: -50 ... +150 °C
T
Process
: -30 ... +250 °C
T
Process
: -30 ... +250 °C
3. Commissioning, operation
Содержание TR21-A
Страница 20: ...EN 14170746 05 03 2022 EN DE FR ES WIKA additional information model TR21 Ex i 20...
Страница 36: ...DE WIKA Zusatzinformation Typ TR21 Ex i 36 14170746 05 03 2022 EN DE FR ES Anlage 2 EU Konformit tserkl rung...
Страница 38: ...DE WIKA Zusatzinformation Typ TR21 Ex i 38 14170746 05 03 2022 EN DE FR ES...
Страница 56: ...FR 14170746 05 03 2022 EN DE FR ES Informations suppl mentaires WIKA type TR21 Ex i 56...
Страница 74: ...14170746 05 03 2022 EN DE FR ES WIKA additional information model TR21 Ex i 74...
Страница 75: ...14170746 05 03 2022 EN DE FR ES WIKA additional information model TR21 Ex i 75...