EN
WIKA operating instructions models TGS55, TGS73 with 831 (Ex)
14327097.02 09/2019 EN/DE/FR/ES
27
8. Dismounting, return and disposal
Personnel
: Skilled personnel
Tools
: Suitable spanner
WARNING!
Physical injuries and damage to property and the
environment through residual media
Residual media in the dismounted instrument can result in a
risk to persons, the environment and equipment.
▶
Observe the information in the material safety data sheet
for the corresponding medium.
▶
Wash or clean the dismounted instrument, in order to
protect persons and the environment from exposure to
residual media.
8.1 Dismounting
WARNING!
Risk of burns
During dismounting there is a risk of dangerously hot media
escaping.
▶
Let the instrument cool down sufficiently before
dismounting it!
DANGER!
Danger to life caused by electric current
Upon contact with live parts, there is a direct danger to life.
▶
The dismounting of the instrument may only be carried out
by skilled personnel.
▶
Remove the thermometer once the system has been
isolated from power sources.
8. Dismounting, return and disposal