23
EN
ADPR1X914124.02 06/2021 EN/DE
WIKA operating instructions, models F2220, F2221, F2226
9. Specifications
Model F2226
Rated force F
nom
kN
10, 20, 30, 40,
50, 75, 100, 200
300, 500, 1,000, 1,500,
2,000, 2,200, 3,000, 3,300
Relative linearity error d
lin
≤ ±0.15 % F
nom
≤ ±0.20 % F
nom
Relative creep, 30 min.
≤ ±0.1 % F
nom
Relative reversibility error v
≤ ±0.15 % F
nom
≤ ±0.20 % F
nom
Relative span in unchanged
mounting situation b
rg
≤ ±0.05 % F
nom
Relative deviation of zero signal d
S, 0
≤ ±1 % F
nom
Temperature effect on the zero signal TK
0
< ±0.05 % of F.S./10 K
Temperature effect on the characteristic
value TK
C
< ±0.05 % Reading/10 K
Limit force F
L
150 % F
nom
Breaking force F
B
> 300 % F
nom
Permissible vibration loading per
DIN 50100 F
rb
±70 % F
nom
Rated displacement s
nom
< 0.4 mm
Material of the measuring body
Stainless steel
Service temperature range B
T, G
-54 ... +121°C
Rated temperature range B
T, nom
15 ... 71°C
Output signal (rated characteristic value) C
nom
2 mV/V
Input / Output resistance R
e
/R
a
350 Ω
Insulation resistance R
is
> 2 GΩ
Electrical connection
Coupler connector, 6-pin
Voltage supply
without amplifier
DC 2 … 12 V (max. 15 V)
with cable amplifier
DC 12 … 28 V for output 0(4) … 20 mA
with integrated amplifier
DC 0 … 10 V
Protection (acc. to IEC/EN 60529)
IP66
Options
■
Force introduction components
■
Integrated amplifier
■
Extended temperature ranges
■
Other thread sizes
■
Other bridge resistance
■
Connector / plug protection
■
Internal / external thread