6 Commissoning, operation
30
WIKA operating instructions digital indicator DI30
6.7 Program number table
The program table lists all the program numbers (PN) with their function,
range of values, default values and user level.
PN
Function
Range of value
De-
fault
User
level
0
Measuring input
Parameters 1 to 4 make
use of the factory
calibration.
Current, Voltage:
0 = Sensor calibration
1 = 0 ... 20 mA
2 = 4 ... 20 mA
3 = 0 ... 10 V
4 = 0 ... 5 V
2
2
1
Scaling final value
-999 ... 9999
1000
2
2
Scaling starting value
-999 ... 9999
0
2
3
Number of decimal places
0 = 0
1 = 0.0
2 = 0.00
3 = 0.000
0
2
5
Offset shift on display
value
-999 … 9999
0
2
10
Zero point suppression
0 … 999
0
2
General settings
13
Indication time
0.1 ... 10.0
1,0
2
14
Measuring time
0.01 ... 10.0
0.1
2
Security settings
50
Access code
0000 ... 9999
0000
8
51
Locking code
0000 ... 9999
0000
0
52
User level
1 ... 8
8
0
Function of the zero key
54
Actuator via zero key
0 = deactivated
1 = TARA
2 = Offset shift
3 = HOLD
0
2
Flashing of the LED-display
59
Display flashing (approx.
0.5 seconds)
No flashing
Flashes at alarm 1
Flashes at alarm 2
Flashes at alarm 1 and 2
0 = no flashing
1 = flashes at 1
2 = flashes at 2
3 = flashes at 1 and 2
0
4