background image

Entering water temperature 15

O

C

Assembly

Caution!

Disconnect the heater from power supply prior to dismantling it from tap

assembly. Otherwise heating element can be damaged.

Mounting without conformity to manufacturer’s instruction result in dep-

rivation of guarantee.

Clean water tube thread of dirt to eliminate filter blockage. Fit tap assembly (9) sealing thread with

adequate sealing material. Feed-pipe should not be retreated into wall. If anyway it happened,

extension of 1/2 should be used.

Connect heater to the tap assembly (9) with nuts (5), gaskets (4) and water filter (3).

Open water flow to the tap (9). Because dirt can flow out and cause filter or water sprinkler plug-

ging, therefore is necessary:

1 – Screw off sprinkler (6) from drain tube.

2 – Open cold water tap (8) for few seconds.

3 – Release air-plug by opening hot water tap (7) for few seconds.

4 – Screw in sprinkler (6) into drain tube.

Check tightness of water connections. Connect heater to power installation and switch on. Correct

water temperature (chapter 4).

Lack of water filter can cause damage to the heater because of dirt.

4. Temperature adjustment

Caution!

Water temperature on heater exit depends of:

– water flow intensity (lower flow – higher temperature,

higher flow – lower temperature)

– entering water temperature

– voltage drop during heater work

5

Содержание PERFECT 350 ELECTRONIC

Страница 1: ...Water flow heaters PERFECT 350 400 450 500 electronic ASSEMBLY AND OPERATION MANUAL EN ...

Страница 2: ...vice can only work in position showed on drawing below Trying to start the device in position other than proper one will result in damaging a heating element and deprivation of guarantee drawing No 1 2 Safety regulations Connection to the electric power installation and measurement of earthing effectiveness should be made by qualified electrician Heater must be earthed or neutralized Heater must b...

Страница 3: ...to be splashed with water Water tap drain tube sprinkler strainer should be cleaned regularly 3 Heater assembly Wiring system b power net system TN S F2 over current bipolar switch L live lead N neutral lead PE protective lead Minimum cross section of wires PERFECT 350 ELECTRONIC 1 5 mm2 PERFECT 400 450 500 ELECTRONIC 2 5 mm2 Fuse rating PERFECT 350 ELECTRONIC 20A PERFECT 400 450 500 ELECTRONIC 25...

Страница 4: ...view 1 Control lamp signaling heater s switching on 2 Water temperature adjusting screw 3 Water filter 4 Gaskets 5 Water tap nuts 6 Drain tube sprinkler strainer 7 Hot water knob 8 Cold water knob 9 Water tap assembly 4 ...

Страница 5: ...askets 4 and water filter 3 Open water flow to the tap 9 Because dirt can flow out and cause filter or water sprinkler plug ging therefore is necessary 1 Screw off sprinkler 6 from drain tube 2 Open cold water tap 8 for few seconds 3 Release air plug by opening hot water tap 7 for few seconds 4 Screw in sprinkler 6 into drain tube Check tightness of water connections Connect heater to power instal...

Страница 6: ...y prior to dismantling it from tap assembly Otherwise heating element can be damaged 1 Turn on hot water knob 2 2 Put screw driver to a hole 1 located on the right side of housing 3 Turn screw driver left or right to suppress water flow in order to reach requested temperature 6 ...

Страница 7: ...ter 5 water pressure in water system too low lack of power supply fuse blown out Heater does not warm up water but control lamp lights voltage too low supplying installation overloaded temperature of entering water too low water flow too high adjust water flow according to chapter 4 Water temperature on heater exit too low water flow too high adjust water flow according to chapter 4 temperature of...

Страница 8: ...r pressure 0 6 MPa 0 6 MPa 0 6 MPa 0 6 MPa Min entering water pressure 0 04 MPa 0 04 MPa 0 05 MPa 0 05 MPa Water pressure on exit 0 Bar 0 Bar 0 Bar 0 Bar Min water resistance at 15O C 1300Wcm 1300Wcm 1300Wcm 1300Wcm Splash proofing IP25 IP25 IP25 IP25 Min switching on water flow 1 2 l min 1 3 l min 1 4 l min 1 5 l min Max entering water temp 32O C 32O C 32O C 32O C Outfit Water flow heater 1 pc Wa...

Страница 9: ...ilers of such equipment as well as by gmina organizational units conducting the activity in the scope of collecting waste The above statutory obligations have been introduced in order to limit the amount of waste created from deteriorated electric and electronic equipment as well as to ensure the proper level of collecting recovering and recycling the waste equipment In the equipment there are no ...