Introduction
The voltage tester 45217 is universally applicable tester for voltage testing, continuity
testing, rotary field testing and trip test of RCD. The tester is constructed according to
the latest safety regulations and guarantee safe and reliable working.
The voltage tester 45217 is characterized by the following features
• Designed to meet international safety standards. IEC 61243-3:2014
• Measurement category (CAT.) IV 600 V, III 1,000 V
• AC and DC voltage test from 0,5 V to 1,000 V AC and 1,500 V DC
• Polarity indication
• Single-pole phase test
• Phase rotation test
• Trip test of RCD
• Continuity test
• Resistance test
• Auto Power ON / OFF
• Torch light
• IP64 (IEC 60529)
• Vibration motor
• TRMS
After unpacking, check that the instrument is undamaged. The product
package comprises
• 1x Tester 45217
• 2x 4 mm test tip adapters
• 2x CAT III/ 1,000 V test tip cover
• 2x Batteries 1.5 V (AAA, IEC LR03)
• 1x Instruction manual
Safety measures
The testers have been constructed and tested in accordance with the safety
regulations for voltage testers and have left the factory in a safe and perfect con-
dition. To maintain this condition, the user must observe the safety instructions
in this manual.
The operating instructions contain information and References required for
safe operation and use of the tester. Before using the tester, read the operating
instructions carefully and follow them in all respects.
Danger of electric shock and other dangers
To avoid an electric shock, observe the precautions when working with voltages
exceeding 120 V (60 V) DC or 50 V (25 V) eff AC. In accordance with DIN VDE
these values represent the threshold contact voltages (values in brackets refer to
limited ranges, e.g. in agricultural areas).
The tester must not be used with the battery compartment open.
Before using the tester, ensure that the test lead and device are in perfect wor-
king order. Look out e.g. for broken cables or leaking batteries.
Содержание 45217
Страница 4: ......
Страница 115: ...RU 113 1000 1500 15 C 50 C 85 EMC...
Страница 116: ...114 L1 L2 O R 12 4 GS38 L1 L2 2 3 8 9 10 1 11 7 6 5 12 4 14 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14...
Страница 117: ...RU 115 6 L2 30 30 C L1 L2 2 50 120 AC 12 DC 12V DC 12V L2 DC DC L R 50 120 0 5 1000 1500 10 0 5...
Страница 118: ...116 L2 100 R L 230 10 30 L PE RCD Rx 500 30 L1 L2 L1 L2 6...
Страница 119: ...RU 117 Spotlight 2 30 30 6 2 HOLD HOLD 16 950 10 120 ELV 50 120 NCV NCV NCV NCV 6...