INSTRUCTION MANUAL
30
Capacitance test
Prior to any capacity test, it must be ensured, that the capacity to be tested is
not live. Failure to comply with this prescription can lead to dangerous corporal
user injuries or cause instrument damage. Additionally, foreign voltages falsify
the measurement result.
Resistors and semiconductor paths in parallel to the capacity cause falsified
measurement results.
• Select Ω
measurement mode via measurement function selection switch.
• If necessary, use SELECT button to set the measurement. Press SELECT button
to cycle through resistance, continuity, diode and capacitance measurements.
• Connect the black test lead to the COM socket and the red test lead to the
mV Ω μmA °C Hz
socket.
• Connect test leads to UUT.
• Read the measurement result displayed on the display.
Temperature measurement
Prior to any temperature measurement it has to be ensured that the surface
to be measure is not live. Failure to comply with this prescription can lead to
dangerous corporal user injuries or cause instrument damage.
To avoid burns only touch UUT by means of the thermocouple.
• Select °C measurement mode via measurement function selection switch.
• Connect the minus pole to the COM socket and the plus pole lead to the
mV Ω μmA °C Hz
socket.
• Temperature probe leads to UUT.
• Read the measurement result displayed on the display.
Current measurement
Ensure that the measurement circuit is not live when connecting the measure-
ment instrument.
The instruments may only be used in current circuits protected with 16 A up to a
nominal voltage of 1,000 V. The nominal cross section of connecting line has to
be respected and a safe connection has to be ensured.
After instruments fuse tripping eliminate the cause for the tripping prior to fuse
replacement.
Current measurement μA AC
• Select μA measurement mode via measurement function selection switch.
• Multimeter will automatically enter μA AC mode.
• Connect the black test lead to the COM socket and the red test lead to the
mV Ω μmA °C Hz
socket.
• Connect test leads to UUT.
• Read the measurement result displayed on the display.
Current measurement μA DC
• Select mA measurement mode via measurement function selection switch.
• Press “Select” button once to enter DC mode.
• Connect the black test lead to the COM socket and the red test lead to the
mV Ω μmA °C Hz
socket.
• Connect test leads to UUT.
• Read the measurement result displayed on the display.
Current measurement mA AC
• Select mA measurement mode via measurement function selection switch.
• Multimeter will automatically enter mA AC mode.
Содержание 45215
Страница 207: ...RU 207 O II DIN EN 61140 WEEE 2012 19 5 6 6 8 8 13 14 14 NCV 15 15 15 15 16 16 16 T 17 18 18 19 19 19 19 O 19...
Страница 209: ...RU 209 2 x 1 5 IEC LR03 1 x B 2 120 60 50 25 VDE B...
Страница 215: ...RU 215 EF 120 60 50 25 VDE VAC VSCAN COM mV mA C Hz VDC VSCAN COM mV mA C Hz COM mV mA C Hz SELECT mV DC COM mV mA C Hz...
Страница 216: ...216 NCV NCV 45215 NCV EF COM mV mA C Hz SELECT SELECT COM mV mA C Hz SELECT SELECT COM mV mA C Hz 30...
Страница 218: ...218 COM mV mA C Hz COM mV mA C Hz A COM 10A A COM 10A 49 77 22 959 0...
Страница 219: ...RU 219 1 5 IEC LR03 A F 600 1000 6 3 x 32 A F 10 A 1000 6 3 x 32...