24
3.2
Troubleshooting
Box rotator model
Problem
Solution
All models.
The box rotator is not in a horizontal position if
the piston rod of the cylinder is fully retracted.
Loosen the clamping bolts at the ends of
the piston rod and screw/unscrew the
piston into/from the block. Proceed until
the fork carrier is in a horizontal position
with the back plate. Tightly secure the
clamping bolts.
The cylinder head has clearance in the cylinder
tube.
If there is any clearance, please contact
WIFO-Anema BV. We strongly recommend
not to use the machine till further
instructions.
K54A/K54C/SK54A/SK54C
There is some play in the bearing (sleeve bearing)
on the shaft of the fork positioner.
The bearing is worn-out and must be
replaced by a skilled mechanic.
K54A-Z/K54C-Z/SK54A-
Z/SK54C-Z
There is some play in the bearing (tapered roller
bearing) on the shaft of the fork positioner.
Loosen the lock nuts of the socket set
bolts; fasten the socket set bolts by hand
in the locking plate and turn one quarter
back. Proceed with tightening the lock
nuts.
Table 3.2.1-Troubleshooting
Please contact your dealer for any further concerns you may have. He will be pleased to assist.
Содержание K54A-I
Страница 2: ......
Страница 12: ...10 2 2 K54A I and K54C I 2 2 1 Parts list Figure 2 2 1 Parts drawing for K54A I and K54C I...
Страница 15: ...13 2 3 K54A O and K54C O 2 3 1 Parts list Figure 2 3 1 Parts drawing for K54A O and K54C O...
Страница 18: ...16 2 4 K54A Z O K54C Z O 2 4 1 Parts list Figure 2 4 1 Parts drawing for K54A Z O and K54C Z O...
Страница 21: ...19 2 5 SK54A O SK54C O 2 5 1 Parts list Figure 2 5 1 Parts drawing for SK54A O and SK54C O...
Страница 29: ......
Страница 30: ......
Страница 31: ......