Installation instruction (translation from original)
wienet
3G HSPA+ UR5i
83.041.0XXX.X
HSPA+ Router
Wieland Electric GmbH
Brennerstraße 10 – 14
96052 Bamberg
Phone +49 951 9324-0
Fax
+49 951 9324-198
Doc. #
BA000798
– 11/2020 (Rev. F)
wienet
3G HSPA+ UR5i
EN
NOTE
Personnel which installs, programs, operates or maintains this device must have read and
understood these instructions.
CAUTION
•
Personnel must be familiar with all the warnings, notes and measures described in these
operating instructions.
•
Protective measures and mechanisms must correspond to applicable regulations.
•
Damaged products must neither be installed nor put into operation. In case of a defect,
please return the device to Wieland Electric.
•
Only connect or disconnect the device when de-energized!
•
Do not insert any objects into the device!
•
Keep the device away from water and naked flames!
1
Function description
The UMTS/HSPA+ router is a compact modular electronic device which enables wireless
data transfers using UMTS, HSPA+, GPRS und EDGE technologies.
•
PC connection over Ethernet interface
•
Automatic establishment and maintenance of GPRS connection
•
Integrated DHCP server for easy installation and Internet access
•
USB 2.0-Host interface
2
Front view
wienet
UR5i V2 (Basic)
wienet
UR5i V2 (Full)
LED
Color
State of LED
Description
PWR
green
LED flashes
The router is ready.
LED on
The router is being started.
DAT
red
LED flashes
Communication in progress
WAN
yellow
LED on
Connection active
USR
yellow
–
Can be assigned by the user
OUT
green
LED on
Digital output is active.
IN
green
LED on
Digital input is active.
ETH
green
LED on
100 MBit/s are active.
LED off
10 MBit/s are active.
yellow
LED on
Network cable is connected.
LED flashes
Data transfer is taking place.
LED off
Network cable is not connected.
SIM1
yellow
LED on
SIM card 1 is active.
3
Connection assignment and wiring
24 VDC supply
Binary inputs and outputs
4
Access to the router
1.
Insert the SIM card (see section 5 "Inserting SIM card").
2.
Connect the antenna ("ANT" port).
3.
Connect the power supply ("PWR" port) to the router.
4.
Connect your PC to the router ("ETH" port) via Ethernet cable.
5.
Change the network settings on the PC so that it automatically receives an IP address.
6.
The router is parameterized via web browser. Login parameters to web interface:
Address:
http://192.168.1.1
User name:
root
Password: See label on the product
P
xxxxxxxx
h
NOTE
Port ETH are not compatible with POE (Power Over Ethernet).
5
Inserting the SIM card
1.
Press the small yellow button to eject the card holder.
2.
Insert the SIM card into the card holder and slide it into the SIM card
reader (see figure).
6
Dimension in mm
7
Factory settings (reset)
The reset button ("RST", on the back) resets the factory settings, including the IP address
and access data. Push the reset button with a paper clip for approx. 3 seconds when the
router is switched on. Wait for approx. 10 seconds until the web interface has reloaded and
then refer to section 4 "Access to the router".
8
Technical data
Connection data
Input voltage
10 – 30 VDC
Reverse polarity protection
built in
Supply current
max. 600 mA
Power consumption
300 mW
up to 3.5 W (GPRS transmission)
up to 5.5 W (UMTS&HSPA+ transmission)
Binary input and output
3-pin terminal
Out / GND / In
Output
120 mA / max. 30 V
Input
reed contact; with trigger level 1.3 – 1.4 V
General Data
Operating environment temperature -30 … +60 °C
Storage temperature
-40 … +85 °C
Protection type
IP20
Installation position
Operator definable
Dimensions / installation
42 × 80.5 × 113.5 mm / rail DIN 35 mm or Desktop
Weight
ca. 280 g (metal housing)
Antenna connection
SMA-50 Ohm
UMTS
Max. Download 21.1 MBit/s
Max. Upload 5.7 MBit/s
Frequency; transmission power
HSPA+:
900 / 1800 Mhz;
max. Power 25 dBm
UMTS:
900 / 1800 / 2100 Mhz;
max. Power 25 dBm
GPRS/EDGE
: 900 / 1800 Mhz;
max. Power 33 dBm
Wi-Fi:
2.4/5 GHz;
max. Power 17.3 dBm
Standard user interfaces
LAN
1× Ethernet (10/100 MBit/s)
USB
1× USB 2.0 Typ A Host
Port 1
1× Port 1 (without function)
Binary IN / OUT
2× In / 1× Out
SIM card
1× SIM card reader
Standards
CE
CE:
Hereby, Wieland Electric GmbH declares that the
wienet
3G HSPA+ UR5i is in
compliance with the following European directives:
RED directive 2014/53/EU, RoHS directive 2011/65/EU.
The complete EU Declaration of Conformity is available with the respective part number
under e.g.
https://eshop.wieland-electric.com/products/83.041.0045.1
in the register
"Downloads".
9
Included accessories (see type)
•
Crossover UTP cable
•
External antenna
•
Fixing clip for DIN rail
10
Optional extension modules
Item no.
Type
F0.000.0049.7
VPN ACC WR-RS232
F0.000.0049.8
VPN ACC WR-RS422/485
F0.000.0049.9
VPN ACC WR-IO
F0.000.0050.0
VPN ACC WR-ETH
The compact version (v2c / 83.041.04X5.3) is not extendible.
11
Further types / Item numbers
Item no.
Type
Interfaces
Antennas
83.041.0040.1 UR5i SLv2
LAN, USB, DI, DO, 1× SIM
ANT, DIV
83.041.0045.1 UR5i SLv2 ETH
2× LAN, USB, DI, DO, 1× SIM
ANT, DIV
83.041.0400.1 UR5iv2f SL
LAN, USB, DI, DO, 2× SIM
ANT, DIV
83.041.0405.3 UR5i v2c SL ETH
2× LAN, 2× SIM
ANT, DIV
83.041.0465.3 UR5i v2c SL ETH WIFI
2× LAN, 2× SIM, WIFI
ANT, DIV, WIFI
You can find more information in the manual and accessories at