Installation instructions (translation from original)
gesis®
GST18i3, GST18i5, GST18i6
GST18i3 / GST18i5 / GST18i6 and mounting plate
07.413.6853.X
Wieland Electric GmbH
Brennerstraße 10 – 14
96052 Bamberg
Phone +49 951 9324-0
Fax
+49 951 9324-198
www.wieland-electric.com
Doc. #
BA001030
– 10/2019 (Rev. B)
gesis
® GST18®
EN
92.030.3X53.X
92.050.3X53.X
92.060.3X53.X
INFO
•
All
gesis®
components may only be installed, commissioned and serviced by qualified
electricians.
•
Persons, who install, operate or maintain this device must have read and understood
these instructions.
•
The relevant standards, guidelines, regulations and provisions of the respective country
must be observed.
•
Protective measures and mechanisms must correspond to applicable regulations.
•
Damaged products may neither be installed nor operated.
•
In case of a defect, please return the component to Wieland Electric.
•
Never use components from third-party manufacturers. No guarantee shall be offered
for damage resulting from a combination with third-party components.
•
Please keep these instructions in a safe place for later reference.
CAUTION
•
Installation connector systems must only be connected and disconnected without load.
•
No hazardous interchangeability with systems based on IEC 60309, IEC 60320, IEC 60906
and with national male and socket systems for home use.
•
Interchangeability between installation connector systems from different manufacturers
is not automatically prevented by compliance with EN 61535.
•
A potential hazardous interchangeability with installation connector systems by the
same manufacturer is not automatically eliminated by compliance with IEC 61535.
•
Compatibility with products from other manufacturers cannot be guaranteed.
•
Installation connectors do not replace national household connector system.
•
In easily accessible areas, unused connectors must be fitted with cover cap and the test
openings must be closed off with the molded cover.
Instructions using the example of a 5-pole dis-
tributer. Proceed identically for 3-pole distrib-
utors and 5-pole distributors with phase selec-
tion.
1
Mounting on carrier plate
1.
Bend fixing clip up and down. The fixing
clip will break off.
2.
Remove fixing clip.
3.
Push the fixing clip through the mount-
ing hole with the prongs facing up.
Align the plate and the pre-cut hole of
the cable routing and push the fixing
clip until it snaps into place with a click
sound.
4.
Alternatively, use the existing holes as screw attachment.
2
Cascading
1.
Push screwdriver under locking slide and push screwdriver downwards.
2.
Pull locking slide upwards.
3
Mounting on carrier plate (if mounting possibility available)
Mounting in detail
4
Dismounting of carrier plate with screwdriver
5
Usage with panel connection/preassembled cables
T-distributors have no integrated lock on the vertical output because they can be plugged
directly into a device. For usage with preassembled cables an additional lock (accessories) is
necessary.
6
Technical data
Rated voltage
3-pole 250 V; 5- and 6-pole 250/400 V
Rated current
20 A
Protection class
I
Protection type
IP20
3. Attach T-distributor onto the next until locking
mechanism audibly locks.
Click!
Click!
Click!
1
2
3
1
2
1
2
Click!
1
2
1
2
1
2
1
2
3
3