Installation instruction (translation from original)
wienet
AP ETH-A
83.040.0050.0
AP ETH-A-A
83.040.0051.0
WLAN Access Point
Wieland Electric GmbH
Brennerstraße 10 – 14
96052 Bamberg
Phone +49 951 9324-0
Fax
+49 951 9324-198
Doc. #
BA001032
– 11/2020 (Rev. C)
wienet
AP ETH-A
2
EN
NOTE
Personnel which installs, programs, operates or maintains this device must have read and
understood these instructions.
WARNING
•
Personnel must be familiar with all the warnings, notes and measures described in these
operating instructions.
•
Protective measures and mechanisms must correspond to applicable regulations.
•
Damaged products must neither be installed nor put into operation. In case of a defect,
please return the device to Wieland Electric.
•
Only connect or disconnect the device when de-energized.
•
The unit must not be opened!
•
Do not insert foreign objects into the device!
•
Keep the device away from water and fires!
1
License information
This device incorporates software from third-party providers under the license conditions of
GNU General Public License Version 2. You are permitted to modify or distribute this free
software under the conditions of the GNU General Public License. If required, you can request
the source code of the software covered by the GNU General Public License. You can find
further information at:
https://dev.openwrt.org/browser/trunk/LICENSE
http://www.gnu.org/licenses/gpl-2.0
2
Function description
The
wienet
AP ETH is a WLAN Access Point for devices that communicate wirelessly, and it
can be configured as a repeater. It can also be connected to devices that do not have their
own WLAN adapter. It is delivered configured with the factory settings and ready for
immediate use. The WAP can be configured for specific requirements via an integral web
interface. Access is possible via LAN or WLAN.
3
Display and operating elements
LED
Color
Description
Function
STATUS Green
LED off >10 s
LED flashes
LED lights up
No power supply available
The Access Point is starting up.
The Access Point is ready for use.
DATA
Yellow
LED off >10 s
LED lights up
LED flickers
No power supply available or
RJ45 socket not connected
RJ45 socket connected without activity
RJ45 socket connected with activity
Buttons
Description
Function
RES
Press RES <3 s
Press RES 5–30 s
Restart
Restart with factory settings
After switching on the power supply, it takes approx. 10 seconds for the green LED to start
flashing and about another 25 seconds for the green LED to light up. A flashing green LED
indicates that the
wienet
AP is not yet ready for use (boot procedure or restart), whereas a
continuously lit LED indicates that the device is indeed ready for use (status OK).
The yellow LED lights up briefly when the power supply is switched on. The yellow LED lights
up when there is a LAN connection and flickers to indicate network activity via this
connection.
4
Connection to the Access Point
To ensure that a network connection can be established, your PC must be in the same
network.
4.1
Access via network cable
1.
Connect the power supply.
2.
Connect your PC to the
wienet
AP ("ETH" port) via Ethernet cable.
3.
Enter the IP address of the network adapter manually on the PC:
IP address: 192.168.1.2 – 192.168.1.254
Network mask: 255.255.255.0
4.2
Access via LAN
1.
Only for 83.040.0051.0: Connect the WLAN antenna ("ANT").
2.
Connect the power supply.
3.
Activate the WLAN connection on the PC and connect to the WLAN network.
4.
Enter the IP address of the network adapter on the PC as described in 4.1, step 3:
SSID:
wienet-AP-3P
Password:
wienet123
5
Access to the Access Point web interface
The
wienet
AP is configured via a web interface using a web browser and can be accessed as
follows:
1.
Open the following URL in the browser:
2.
Enter the following password in the opening webpage:
root
The
wienet
AP web interface then opens. If the window does not open, please check the
proxy settings for the browser you are using.
Please do not use a proxy!
6
Individual configuration
The
wienet
AP is delivered configured with the factory settings and ready for immediate use.
The individual configuration is made via the web interface. We recommend performing the
initial configuration using the LAN interface of the device.
For your own security, change the password for accessing the web interface, the ESSID and
the WLAN password as well as the host name, country code and language, if required.
The IP address must be changed manually after delivery. You can also configure the
wienet
AP as a DHCP client (IP address retrieved from DHCP server) or as a DHCP server (IP
addresses allocated to connected DHCP clients).
Save:
Changes are adopted in the web interface.
Save & Apply:
Changes are transferred to the device additionally to saving.
If changes relevant to the connection are made (e.g. ESSID, IP address, password or WLAN
key), access to the web interface is only possible again after you connect and log on with the
new settings.
7
Load factory settings (reset)
Press the "RES" button at the top left above the ETH port to reset the factory settings,
including the IP address and access data.
Press the "RES" button for 5
–
30 seconds (e.g. using a paper clip) while the
wienet
AP is
ready for use. Then wait until the green LED lights up continuously (after approx. 35 s). The
wienet
AP is now ready for use again.
8
Technical data
Operating voltage connection
Connection type
plug-in female connector strip with screw terminals,
4-pin, color: green
+/
−
= connection for operating voltage
PE = connection for screen grounding
Rated voltage
24 V DC
Voltage range
9 … 28 V DC
Approx. rated current
42 mA (at 24 V DC)
Approx. rated consumption
1 W (at 24 V DC)
Inverse polarity protection
yes
PE connection
yes, for screen grounding
Connector cross section
0.14 … 2.5 mm²
Tightening moment
0.5 … 0.7 Nm
Wire strip length
7 mm
WLAN
Wireless LAN standard
IEEE 802.11 n/g/b
Frequency
2.4 … 2.4835 GHz
Transmission power
<100 mW
Data rate
max. 150 Mbit/s
Safety
WEP, WPA-PSK, WPA2-PSK
Antenna
83.040.0050.0
83.040.0051.0
integrated
RP-SMA socket for external antenna connection
LAN
Connection type
RJ45 socket
Medium
Twisted pair 10/100BaseT
Screen / grounding
PE connection (at operating voltage connection)
Environmental conditions
Usage area
For fixed installation in closed housings, distributors
and switch cabinets, in interior rooms and dry rooms,
weather-proofed, unregulated
Operating environment
temperature
-5 … +55 °C
Storage temperature
-20 … +60 °C
Relative humidity
5% … 93%
Condensation
not permitted
Mounting
Mounting method
mounting on TH 35-7.5 DIN rail
Installation position 83.040.0050.0
83.040.0051.0
Preferably at the start or end of the mounting rail due to
the integral antenna, not in metal housings.
As required, including metal housings; external antenna
positioned outside the housing
Weight
83.040.0050.0
83.040.0051.0
approx. 93 g
approx. 97 g
Dimensions
83.040.0050.0
(W×H×D)
83.040.0051.0
22.5 × 96.5 × 91.5 mm
22.5 × 96.5 × 101.5 mm
Standards
EN 61000-6-2, EN 300328, EN 301489-1
Accessories for
83.040.0051.0 WLAN magnetic base antenna, article no. F0.000.0037.4
(not included in delivery)
CE:
Hereby, Wieland Electric GmbH declares that the
wienet
AP ETH-A-x is in compliance
with the following European directives:
RED directive 2014/53/EU, RoHS directive 2011/65/EU.
The complete EU Declaration of Conformity is available with the respective part number under
e.g.
https://eshop.wieland-electric.com/product/83.040.0050.0
in the register "Downloads".
w
ie
ne
t
A
P E
TH
-A
(83.
040.
0050
.0
)
w
ie
ne
t
A
P E
TH
-A
-A
(83.
040
.0051.
0)