Installation instruction (translation from original) 

 

 

wienet

 

AP ETH-A

 

 

 

83.040.0050.0 

 

AP ETH-A-A

 

 

 

83.040.0051.0 

 

 

 

WLAN Access Point 

Wieland Electric GmbH 

Brennerstraße 10 – 14 

96052 Bamberg 

Phone  +49 951 9324-0 

Fax 

+49 951 9324-198 

[email protected] 

www.wieland-electric.com  

 

 

Doc. # 

BA001032 

– 11/2020 (Rev. C) 

wienet

 AP ETH-A 

EN

 

NOTE 

Personnel which installs, programs, operates or maintains this device must have read and 

understood these instructions. 

 

WARNING 

 

Personnel must be familiar with all the warnings, notes and measures described in these 

operating instructions. 

 

Protective measures and mechanisms must correspond to applicable regulations.  

 

Damaged products must neither be installed nor put into operation. In case of a defect, 

please return the device to Wieland Electric. 

 

Only connect or disconnect the device when de-energized. 

 

The unit must not be opened! 

 

Do not insert foreign objects into the device!  

 

Keep the device away from water and fires! 

 

1

 

License information 

This device incorporates software from third-party providers under the license conditions of 

GNU General Public License Version 2. You are permitted to modify or distribute this free 

software under the conditions of the GNU General Public License. If required, you can request 

the source code of the software covered by the GNU General Public License. You can find 

further information at:  

https://dev.openwrt.org/browser/trunk/LICENSE

 or 

http://www.gnu.org/licenses/gpl-2.0

 

2

 

Function description 

The 

wienet 

AP ETH is a WLAN Access Point for devices that communicate wirelessly, and it 

can be configured as a repeater. It can also be connected to devices that do not have their 

own WLAN adapter. It is delivered configured with the factory settings and ready for 

immediate use. The WAP can be configured for specific requirements via an integral web 

interface. Access is possible via LAN or WLAN. 

 

3

 

Display and operating elements 

LED 

Color 

Description 

Function  

STATUS  Green 

LED off >10 s 

LED flashes 

LED lights up 

No power supply available 

The Access Point is starting up. 

The Access Point is ready for use. 

DATA 

Yellow 

LED off >10 s 

 

LED lights up 

LED flickers 

No power supply available or  

RJ45 socket not connected  

RJ45 socket connected without activity 

RJ45 socket connected with activity 

Buttons 

Description 

Function 

RES 

Press RES <3 s 

Press RES 5–30 s 

Restart 

Restart with factory settings 

After switching on the power supply, it takes approx. 10 seconds for the green LED to start 

flashing and about another 25 seconds for the green LED to light up. A flashing green LED 

indicates that the 

wienet

 AP is not yet ready for use (boot procedure or restart), whereas a 

continuously lit LED indicates that the device is indeed ready for use (status OK). 

The yellow LED lights up briefly when the power supply is switched on. The yellow LED lights 

up when there is a LAN connection and flickers to indicate network activity via this 

connection. 

4

 

Connection to the Access Point 

To ensure that a network connection can be established, your PC must be in the same 

network. 

4.1

 

Access via network cable 

1.

 

Connect the power supply. 

2.

 

Connect your PC to the 

wienet

 AP ("ETH" port) via Ethernet cable. 

3.

 

Enter the IP address of the network adapter manually on the PC: 

IP address: 192.168.1.2 – 192.168.1.254 

Network mask: 255.255.255.0 

 

4.2

 

Access via LAN 

1.

 

Only for 83.040.0051.0: Connect the WLAN antenna ("ANT"). 

2.

 

Connect the power supply. 

3.

 

Activate the WLAN connection on the PC and connect to the WLAN network. 

4.

 

Enter the IP address of the network adapter on the PC as described in 4.1, step 3: 

SSID: 

wienet-AP-3P

 

Password: 

wienet123

 

 

 

5

 

Access to the Access Point web interface 

The 

wienet

 AP is configured via a web interface using a web browser and can be accessed as 

follows: 

 

1.

 

Open the following URL in the browser

http://192.168.1.1

  

2.

 

Enter the following password in the opening webpage: 

root

 

 

The 

wienet

 AP web interface then opens. If the window does not open, please check the 

proxy settings for the browser you are using.

 Please do not use a proxy!

 

6

 

Individual configuration 

The 

wienet

 AP is delivered configured with the factory settings and ready for immediate use. 

The individual configuration is made via the web interface. We recommend performing the 

initial configuration using the LAN interface of the device. 

For your own security, change the password for accessing the web interface, the ESSID and 

the WLAN password as well as the host name, country code and language, if required. 

The IP address must be changed manually after delivery. You can also configure the 

wienet

 AP as a DHCP client (IP address retrieved from DHCP server) or as a DHCP server (IP 

addresses allocated to connected DHCP clients). 

 

Save:

 Changes are adopted in the web interface.  

Save & Apply:

 Changes are transferred to the device additionally to saving. 

 

If changes relevant to the connection are made (e.g. ESSID, IP address, password or WLAN 

key), access to the web interface is only possible again after you connect and log on with the 

new settings. 

7

 

Load factory settings (reset) 

Press the "RES" button at the top left above the ETH port to reset the factory settings, 

including the IP address and access data. 
Press the "RES" button for 5 

– 

30 seconds (e.g. using a paper clip) while the 

wienet

 AP is 

ready for use. Then wait until the green LED lights up continuously (after approx. 35 s). The 

wienet

 AP is now ready for use again. 

8

 

Technical data 

Operating voltage connection 

Connection type  

plug-in female connector strip with screw terminals, 

4-pin, color: green 

+/

  = connection for operating voltage 

PE   = connection for screen grounding 

Rated voltage 

24 V DC 

Voltage range 

9 … 28 V DC 

Approx. rated current  

42 mA (at 24 V DC) 

Approx. rated consumption  

1 W (at 24 V DC) 

Inverse polarity protection 

yes 

PE connection 

yes, for screen grounding 

Connector cross section 

0.14 … 2.5 mm² 

Tightening moment 

0.5 … 0.7 Nm 

Wire strip length 

7 mm 

WLAN 

Wireless LAN standard 

IEEE 802.11 n/g/b 

Frequency 

2.4 … 2.4835 GHz 

Transmission power 

<100 mW 

Data rate 

max. 150 Mbit/s 

Safety 

WEP, WPA-PSK, WPA2-PSK 

Antenna  

83.040.0050.0 

 

83.040.0051.0 

integrated 

RP-SMA socket for external antenna connection 

LAN 

Connection type 

RJ45 socket 

Medium 

Twisted pair 10/100BaseT 

Screen / grounding 

PE connection (at operating voltage connection) 

Environmental conditions 

Usage area 

For fixed installation in closed housings, distributors 

and switch cabinets, in interior rooms and dry rooms, 

weather-proofed, unregulated 

Operating environment 

temperature 

-5 … +55 °C 

Storage temperature 

-20 … +60 °C 

Relative humidity 

5% … 93% 

Condensation 

not permitted 

Mounting 

Mounting method 

mounting on TH 35-7.5 DIN rail 

Installation position 83.040.0050.0 

 

 

83.040.0051.0 

Preferably at the start or end of the mounting rail due to 

the integral antenna, not in metal housings. 

As required, including metal housings; external antenna 

positioned outside the housing 

Weight 

83.040.0050.0 

 

83.040.0051.0 

approx. 93 g 

approx. 97 g 

Dimensions 

83.040.0050.0 

(W×H×D) 

83.040.0051.0 

22.5 × 96.5 × 91.5 mm 

22.5 × 96.5 × 101.5 mm 

Standards 

EN 61000-6-2, EN 300328, EN 301489-1 

Accessories for

 

83.040.0051.0  WLAN magnetic base antenna, article no. F0.000.0037.4 

(not included in delivery) 

CE: 

Hereby, Wieland Electric GmbH declares that the 

wienet

 AP ETH-A-x is in compliance 

with the following European directives: 

RED directive 2014/53/EU, RoHS directive 2011/65/EU. 

The complete EU Declaration of Conformity is available with the respective part number under 

e.g

https://eshop.wieland-electric.com/product/83.040.0050.0

 in the register "Downloads". 

 

w

ie

ne

t

 A

P E

TH

-A

 (83.

040.

0050

.0

 

w

ie

ne

t

 A

P E

TH

-A

-A

 (83.

040

.0051.

0)

 

 

Отзывы: