7
| Technical Parameters
24
Wieland Electric GmbH | BA001037 (Rev. A) | 08/2016
7.3
Type tests and environmental conditions
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure contact
Enclosure air
± 6 kV (crit. A)
± 8 kV (crit. A)
RF field AM
modulated
IEC 61000-4-3
Enclosure
20 V/m (crit. A)
(80 – 2700 MHz)
Fast transient
EN 61000-4-4
Signal ports
Power ports
Ethernet ports
± 2 kV (crit. A)
± 2 kV (crit. A)
± 2 kV (crit. A)
Surge
EN 61000-4-5
Ethernet ports
Power ports
I/O ports
± 2 kV (crit. B), shielded cabel
± 0,5 kV (crit. B)
± 1 kV, L to L (crit. A)
± 2 kV, L to GND (crit. A)
RF conducted
EN 61000-4-6
All ports
10 V/m (crit. A)
(0,15 – 80 MHz)
Radiated emission
EN 55022
Enclosure
Class B
Conducted emission
EN 55022
DC power ports
Ethernet ports
Class B
Class B
Power frequency
magnetic field
EN 61000-4-8
Enclosure
160 A/m (crit. A)
Dry heat
EN 60068-2-2
+75 °C*, 40 % rel. humidity
Cold
EN 60068-2-1
+ 40 °C*
* The temperatures are given for basic version of the router. For example, if the router is equipped with WiFi module,
values are slightly worse.