![widos PSM 10 XHS Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/widos/psm-10-xhs/psm-10-xhs_working-instructions-translation_979332014.webp)
Kunststoffschweißtechnik
Operating and indicating elements
Chapter 4
13.10.2014
Working instructions WIDOS PSM 10 XHS
Page 14 of 29
4.1. Heating element
No.
Denomination
Function
13 On / off switch,
illuminated in red
- as soon as the heating element is turned on, it is heated up.
- lamp is red if connected to the mains
14 D induction
regulator
- adjustment of temperature of the heating element
15 Control lamp, green
We differ between 3 status:
•
Off: signal for the state that the heating element does not heat
up or cool down at the moment.
•
Blinking: The temperature of the heating element stays stable.
This is realized by the pulse-interval relation.
•
ON: signal for the state that the heating element is heated up at
the moment. The desired temperature is not yet reached.
16 Connection cable
- cable for the connection with the local power supply 230 V /
50 Hz, fuse protection 16 A
The heating element is shown in welding position. Slew lever (8) below in arrow direction to
bring the heating element into basic position.
13
14
15
16
(8)