Kunststoffschweißtechnik
Starting and operating
Chapter 5
22.11.2005
Working Instructions WIDOS 4900 CNC 3.0 (110 V)
Page 34 of 76
Display:
2
nd
line:
name of project
WIDOS ............
Enter the name of the project
Continue as described in point 5.11 Welding process.
5.12. Error messages
If during the work with the machine
•
the prescriptions of the DVS are not followed
•
the working steps necessary for the welding processs are not correctly or not at all
performed
•
certain measuring devices do not funtion,
the following error messages will appear on the display:
T
Heating element temperature
A
Adjusting
W
Heating
U
Change over
R
Pressure build-up ramp
t
Joining time
p
Joining pressure
In case of an error, these error codes will also appear in the first line of the display.
All error messages are logged.
5.13. Administration of the welding data
The battery-buffered CNC memory (RAM) can store about 400 weldings.
Make sure not to go over this quantity (in the display the error message
"memory full“ appears) because otherwise the first stored welding will be over-
written.
If necessary, read the welding data out in time.
5.13.1. Printing the welding data from the internal memory (RAM)
When pressing the button <Enter>, the stored welding parameters can be printed or stored on
a PCMCIA card.
Jump for one step back with button <C>.
Display:
2
nd
line:
WIDOS 4900 CNC
22.11.2000 10:10
Basic menu
Current date and time
next menu by pressing <Enter> button