widinovations Confidential ©
33
5.
Maintenance
Improper maintenance can cause serious injury or damage. For this reason, this work may only be carried out by
authorized, trained personnel, who are familiar with, how to operate the machine and in strict observance of all
safety instructions.
Using explosive or flammable cleaning agents presents a risk of fire or explosion:
No flammable or explosive liquids are allowed to be stored near the machine.
CAUTION
Before any maintenance work takes place, ensure that the power supply has been switched off and the system is
turned off.
Maintenance schedule
COMPONENT
DAILY
WEEKLY
MONTHLY
ANNUALLY
Lenses and mirrors
Check and clean if
necessary;
Working area
Remove debris and
clean;
Waste drawer
Remove debris and
clean;
Emergency Buttons
Check visually and
test;
Safety door Sensors
Check visually the
integrity;
Exhaustion entrances
Inspect, clean if
necessary;
Cooling fans and
ventilation openings
Check, clean if
necessary
Chiller unit
Check level, add
distilled water if
necessary
Replace water.
Humidity filter
Check and clean;
Belts
Clean the surface
Clean and adjust*;
Linear rails
Clean and grease*;
* The following maintenance procedures are only allowed to be realized by trained and authorized technical
personnel, according to the indications.
Содержание widlaser C1000
Страница 1: ...USER MANUAL...
Страница 16: ...widinovations Confidential 16 RIGHT SIDE VIEW TOP VIEW 11 12 13 10 14 15 16 11 12 13 14 15 16...
Страница 17: ...widinovations Confidential 17 WORKING AREA 17 18 19 20 17 18 19 20...
Страница 36: ...widinovations Confidential 36 7 Declaration of conformity...
Страница 37: ...widinovations Confidential 37 8 ROHS certificate...