background image

14

15

Positioning the hearing aid

Close the battery drawer completely.

Hold your hearing aid by the extrac-
tion cord with your thumb and fore-
finger.  Slowly  guide  the  hearing  aid 
into your ear canal until you feel re-
sistance. 

Let go of the extraction cord and use 
the  tip  of  your  forefinger  to  gently 
push the hearing aid into your ear un-
til it rests comfortably in your canal. 

To  help  position  the  hearing  aid 
properly you could pull the outer ear 
backwards and upwards with the op-
posite hand.

removing the hearing aid

Gently pull the extraction cord with 
your thumb and forefinger. 

If it is difficult, you can try to move 
the  hearing  aid  carefully  from  side 
to  side  while  pulling  the  extraction 
cord. It may also help to pull the out-
er ear backwards and upwards with 
the opposite hand.

Содержание CLEAR C4-CIC

Страница 1: ...User instructions The clear 440 Series C4 CIC C4 CIC TR model Completely in canal...

Страница 2: ...between the listening programs 24 Zen 24 Cleaning 25 The hearing aid 26 The sound outlet 28 The relief vent 29 The microphone opening 30 nanocare wax guard 31 Changing the NanoCare wax guard 32 Access...

Страница 3: ...ing indicate include information regard ing any special care to be exercised Non ionizing radiation Not for general waste The hearing aid 1 Microphone opening 2 Battery drawer 3 Nail grip 4 On off fun...

Страница 4: ...a relaxing sound background i e music noise source for adults who desire to listen to such a background in quiet Indications for use The devices are indicated for individuals with a range of hearing l...

Страница 5: ...e professional in consultation with you The signal can also be deactivated Adjusting volume via remote control Tone Off Confirming RC program key use Clicking sound Off Changing program via remote con...

Страница 6: ...e the tab has been removed the battery will start functioning after a few seconds CAUTION Do not use batteries if there is a sticky residue from the tab or other unwanted substance as this can cause t...

Страница 7: ...xhausted You should be aware of this possibility in particular when you are in traffic or are otherwise dependent on warning signals Turning the hearing aid on and off The battery drawer of the hearin...

Страница 8: ...gently push the hearing aid into your ear un til it rests comfortably in your canal To help position the hearing aid properly you could pull the outer ear backwards and upwards with the op posite han...

Страница 9: ...ontrol please also refer to the user instructions for this To mute the hearing aid with a remote control Keep pressing the volume down key on the remote control after the long beep tone has sounded an...

Страница 10: ...tender or Phone in the other Zen Special Zen program with up to three different Zen styles If your needs change over time the combination of lis tening programs can be altered Zen program Your hearing...

Страница 11: ...the Zen program is used in a tinnitus management program its wearer may experience some relief from tinnitus Indications for use The Zen program is intended to provide a relaxing sound background i e...

Страница 12: ...ning tinnitus Short press option the program key is pressed for less than a second At most two listening programs can be programmed for Zen Long press option the program key is pressed and held for mo...

Страница 13: ...earing aids will be affected when you change programs Zen This program is accessed via a long press two secs on the RC program key A short press then allows you to cycle through the available Zen styl...

Страница 14: ...ntilate the hearing aid and allow it to dry We recommend that every time you take the hearing aid out of your ear you inspect the sound outlet the microphone opening in the battery drawer and the re l...

Страница 15: ...tlet as this could damage the hearing aid The relief vent If earwax has accumulated in and or around the relief vent opening do as follows Short vent Clean any earwax from the vent as far as the long...

Страница 16: ...hone opening and into the actual microphone inside the hearing aid contact your hearing healthcare professional Do not insert anything into the actual microphone nanocare wax guard The NanoCare wax gu...

Страница 17: ...x guard Turn the holder around so that the new wax guard is in position to be inserted Insert the holder into the open ing of the sound outlet and gen tly press the wax guard into the opening Then pul...

Страница 18: ...e wax guard fits loosely discard it and insert another If the wax guard becomes dislodged from the hearing aid while in the ear canal please contact your physician Do not try to remove the wax guard f...

Страница 19: ...earing healthcare professional Problem Possible cause Solution The hearing aid whistles continuously Your ear is blocked by earwax Contact your ENT doctor physician The hearing aid is not correctly pl...

Страница 20: ...of interference Caring for your hearing aid The hearing aid is a valuable object and should be treated with care Here are some things you can do to prolong the life of your hearing aid CAUTION Turn o...

Страница 21: ...ing aid as this could cause permanent damage to their hear ing When selecting a listening program please remember that there are situations in which it is particularly important to be able to hear the...

Страница 22: ...be excluded that it may cause interference with other equipment such as medical de vices Never try to open or repair the hearing aid yourself Advice NOTE The hearing aid will not restore normal heari...

Страница 23: ...and NOAHlink Center frequency 10 6 MHz 10 6 MHz 10 6 MHz 2 4 GHz hearing aids rC dex Tm dex bluetooth noahlink Channel Single channel radio Single channel radio Single channel radio 5 logical channels...

Страница 24: ...and noise the other side this coordinated action could enhance the relative loudness of the speech sounds to the noise background and improve speech understanding for some wearers More accurate ident...

Страница 25: ...omponents and their intended user scenarios For programming these requirements include a BER Bit Error Rate better than 10 3 at a bitrate of 212 kbits s a semi duplex transmission with a required ackn...

Страница 26: ...tromagnetic environment specified below The customer or the user of a CLEAR series hearing aid should assure that it is used in such an environment emissions test Compliance electromagnetic environmen...

Страница 27: ...1 kV for in put output lines Not applicable Not applicable Not applicable Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth Not applicable Not applicable Not applicable immunity Test ieC...

Страница 28: ...to the frequency of the transmitter Conducted RF IEC 61000 4 6 3 Vrms 150 kHz to 80 MHz 3 Vrms recommended separation distance d 1 2 P Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m d 1 2 P...

Страница 29: ...EAR series hearing aids are intended for use in the elec tromagnetic environment in which RF disturbances are controlled The customer or the user of the CLEAR series hearing aid can help prevent elect...

Страница 30: ...e purchasing a hearing aid Licensed physicians who specialize in diseases of the ear are often referred to as otolaryngologists otologists or otorhinolaryngologists The purpose of medical evaluation i...

Страница 31: ...uarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipme...

Страница 32: ...ration is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of t...

Страница 33: ...and other relevant provisions of Directive 1999 5 EC A copy of the Declaration of Conformity can be found at http www widex com Hearing aids accessories and batter ies should not be disposed of with n...

Страница 34: ...66 67...

Страница 35: ...9 514 0201 041j Printed by HTO 2011 10 9 514 0131 041 01 01v Manufacturer CIB227 0811...

Отзывы: