Line Power VDSL2 Extender Installation Manual                                                                Page  9

 

  WIDEAREA Telecommunication Technology Co.,Ltd 

6. Troubleshooting 

Checks at the Central Office 

 

check that there are no leakage currents on the line (measured at the CO).    With no 

extender on the line, current should be essentially zero.    With a line powered loop 

extender, you will read about 15mA .

 

 

check the VDSL2 DSLAM configur, is band profile 8a,12a,17a or 30a, is PSD mask 

EU32, EU64

 

Checks at the Pedestal 

 

The minimum distance (on 24AWG) from the Central Office for extender installation 

is 3Kft for line power extender. 

 

Is the LED on the extender on?   

 

Is the extender grounded? Bonded? The ground, cable sheath, and extender should all 

be bonded together at the extender and as frequently as possible elsewhere.    Lack of 

bonding will allow significant interference from AC power, AM radio, electric fences 

and similar problems.    Lack of bonding will also make you a prime target for 

lightning and other surges.    If you can’t bond, don’t ground the extender.    If you 

can’t ground, you have to take steps to isolate the enclosure from ground too.   

Grounding & Bonding together is preferred. 

 

Does the loop distance match the installation condition? . If not, re-check distances, 

connections and eliminate loads. 

 

Does modem sync at the pedestal without the extender connected? The sync rate at this 

location is the maximum the extender can deliver down range. If you can't get sync, 

the extender will not work at this location.   

Checks at the Customer Premise 

 

Customer premise should be at least 3Kft (on 24AWG) from the extender for optimal 

performance. It will work at shorter distances with sub-optimal performance. 

 

Does the modem run without errors? 

 

Содержание AER800-1PVL

Страница 1: ...WIDEAREA Telecommunication Technology Co Ltd Line Power VDSL2 Loop Extender Installation Manual Version 1 0 Please read this document carefully before installation...

Страница 2: ...eep this manual handy for ease of reference during installation and troubleshooting The contents of this document may be updated in the future without prior notice This booklet was created with thorou...

Страница 3: ...ations 4 3 Application 4 4 Physical Structure 5 4 1 AER800 1PVL Box 6 4 2 AER800 4PVL Box 6 4 3 AER800 8PVL Box 7 4 4 AER800 C1PVL 7 5 Installation Procedure 7 5 1 Unpack 7 5 2 Line Power VDSL2 Loop E...

Страница 4: ...am bit rate and bring more stable and reliable VDSL2 broadband service to those longer users Feature Fully compatible with ITU T G 993 2 G994 1 Fully compatible with all the VDSL2 equipments which com...

Страница 5: ...Lightning proof grade 4000V 10 700 S Number of supported subscribers AER800 1PVL 1 ADSL subscriber AER800 4PVL 5 ADSL subscribers AER800 8PVL 9 ADSL subscribers Dimension LWH AER800 1PVL Box 160mm 70m...

Страница 6: ...r to CPE 0 6Km 1 8Km 3Kft 6Kft DSLAM CPE 1 5Km 2 7Km 5Kft 9Kft 4 Physical Structure AER800 1PVL Stand alone 1 port unit AER800 4PVL Box A Box for up to 5 AER800 C1PVL cards AER800 8PVL Box A Box for u...

Страница 7: ...y Co Ltd Table 4 Twist pair Connection Description of AER800 1PVL 4 2 AER800 4PVL Box Figure 3 AER800 4PVL Box Color Connection Orange White A B to DSLAM Green White A B to Modem AER800 C1PVL Subscrib...

Страница 8: ...existing loop plant CO connects the line from the DSLAM to AER800 C1PVL CPE connects the line to the customer modem 5 Installation Procedure 5 1 Unpack When unpacking the equipment be sure to check t...

Страница 9: ...ess than 2 5mm2 13 AWG diameter is required as ground wire One end of the wire should connect to Loop Extender s ground terminal The other end of the wire should connect to a good grounding point Grou...

Страница 10: ...s possible elsewhere Lack of bonding will allow significant interference from AC power AM radio electric fences and similar problems Lack of bonding will also make you a prime target for lightning and...

Страница 11: ...p extender is not connected properly Correct the cable connection or check whether the distance between the DSLAM extender and Modem is within recommended values L1 or L2 is too short Check that loop...

Отзывы: