New Generation ADSL Loop Extender Installation Manual Page 5
This publication may not be reproduced in whole or in part without the express written
permission of Widearea.
(
1
)
26 AWG(0.4mm) twist pair
Table 2 -The Demand about Resistance and Distance of 26AWG:
Route
Loop Resistance
Demand Ohms
Distance Demand
kfeet
km
L1(CO-Extender)
470
~
1250
5.5
~
14.8
1.7
~
4.5
L2(Extender-CPE)
28
~
1100
0.3
~
9.8
0.1
~
4.0
L(CO-Extender-CPE)
579
~
1601
8.2
~
19.7
2.5
~
6.0
(
2
)
24 AWG(0.5mm) twist pair
Table 3 -The Demand about Resistance and Distance of 24AWG:
Route
Loop Resistance
Demand Ohms
Distance Demand
kfeet
km
L1(CO-Extender)
396
~
1032
7.5
~
19.7
2.3
~
6.0
L2(Extender-CPE)
17
~
929
0.3
~
17.7
0.1
~
5.4
L(CO-Extender-CPE)
568
~
1445
10.8
~
27.6
3.3
~
8.4
4. Physical Structure
AER800-1PL Box: A Box for 1 AER800-C1PL embedded
AER800-4PL Box: A Box for 5 AER800-C1PL embedded.
AER800-8PL Box: A Box for 9 AER800-C1PL embedded.
AER800-C1PL: One port signal line power ADSL Loop Extender for one ADSL
subscribers, can be inserted into the Box easily.