CAUTION: MUST BE GROUNDED RELIABLY. 

Table 5 - Twist-wires Connection Description of AER800-2P

 

 

CAUTION:MUST BE GROUNDED RELIABLY. 

After  power  on,  the  “STATUS”  LED  should  be  lightened  in  a  few  seconds  and 

remain on during normal system operation. 

  Power up 

After confirming that all the twist-pair cables are connected correctly and 

enclosure is securely installed, power up the system. The ADSL Loop Extender 

will work in 20 seconds after power is supplied stead 

Attention: 

a) “A” and “B” represent A and B wire of the twist-pair. No polarity. 

b) Before power up the system, please make sure all the connections are 

correct. 

c) When the power supply wire is active, do NOT operate the A and B 

wire of the supply pair simultaneously. The A wire and B wire should 

be isolated. 

Cable II 

Cable I 

Color 

Connection 

Color 

Connection 

Blue/White 

unused 

Blue/White   

Remote PWR 

Orange/White   

to DSLAM. 

Orange/White   

to DSLAM. 

Green/White 

to Modem. 

Green/White   

to Modem. 

Brown/White   

unused 

Brown/White   

unused 

Содержание AEC-B1P

Страница 1: ...du Sichuan China Tel 8628 84207501 Fax 8628 84209696 Web Site http www widearea com cn ADSL Loop Extender and ADSL Loop Extender Power Supply AER800 1P 2P AEC B1P Installation Manual Version 004 Pleas...

Страница 2: ...of the product read this manual thoroughly before use Please keep this manual handy for ease of reference The contents of this document may be changed in the future without prior notice This booklet...

Страница 3: ...sion of Widearea Tel 8628 84207501 8628 84207506 Contents 1 Unpack 3 2 Technical Features 3 3 Installation Environment 4 4 Installation Steps 6 5 Troubleshooting 11 6 Techical Assistance Customer Serv...

Страница 4: ...material Inspect equipment for shipping damage including bent or loose hardware and broken connectors If equipment was damaged in transit contact supplier Product list AER800 1P AER800 2P one AEC B1P...

Страница 5: ...ng 0 5A 3 Installation Environment 1 the actual lines connecting of equipment Figure 1 actual lines connecting L1 The signal twist pair connecting ADSL Loop Extender to DSLAM L2 The signal twist pair...

Страница 6: ...ce demand Min Max kfeet km L1 CO Extender 450 1260 5 0 13 0 1 5 4 0 L2 Extender CPE 200 900 2 0 9 5 0 5 3 0 L CO Extender CPE 800 1600 6 5 22 5 2 0 7 0 24 AWG twist pair The demand about resistance an...

Страница 7: ...junction cabinet or on the pole at the middle locality The Power Supply is installed either at CO or at CPE with remote supply The details about ADSL Loop Extender and Power Supply installation are as...

Страница 8: ...Connector Wiring Diagram Three core power cord without plug used for DC48V power input no polarity Three core power cord with plug used for AC110 240V power input Power output 155V power output cable...

Страница 9: ...accessories include power cord for AC 110V AC220V or DC 48V Connect it to the AC 110V AC220V or DC 48V power source with good connection To easy the installation DC power source connection is no polar...

Страница 10: ...ng point Figure 6 AER800 1P 2P installing Outdoors Just as the structure above the ADSL Loop Extender is fixed in the wire rope or in the wall with a fixity Connect the cables Wiring sockets on front...

Страница 11: ...cables are connected correctly and enclosure is securely installed power up the system The ADSL Loop Extender will work in 20 seconds after power is supplied stead Attention a A and B represent A and...

Страница 12: ...scription Possible Reason Suggested Resolution Equipment does not work after power up Status LED is OFF Power supply cable is not correctly connected Check power supply cable connection Power indicato...

Страница 13: ...are not connected properly Correct the cable connection Line quality is worse between CO and CPE side Change good quality cable There is telephone before the splitter on CPE side Discard the telephone...

Страница 14: ...nternet is slow frequent off line problem Affection of computer hardware failures system failures and virus Check computer or take with PC testers and so on to deal with The parallel cable at CPE side...

Отзывы: