TEMPERATURE SETTING
(To be done only when essential)
This mixer has been set in the factory under balanced pressures at 38˚C. Where conditions are
different from the above the temperature of the mixed water may vary from setting. You can adjust the
calibration of the mixer to suit individual requirements.
1. The Valve is set to a maximum 38˚C(red button stop position) this can be change if requrired using
a thermometer to the check the water flow of the valve.
2. If this temperautre is not hot enough, you are able to re-set the temperature.
3. Turn the handle to the red button stop.
4. Remove Handle Cap, then the Handle Screw, then the Handle.
5. Turn the valve until the temperature is at the required level. Test again using a thermometer.
6. When this is temperature is reached re-fit the components, so that the red button stops at your new
set temperature.
Handle Cap
Handle Screw
Handle
Thermostatic Stop
Valve
CLEANING FILTER
Through years of use impurities and lime scale could restrict flow of water through the filters of the
cartridge. To clean the filter shut off water supply to both inlets. Unscrew mixer and clean filters.