INDURO 145 OWNERS MANUAL 

5. OPERATION 

SAFE MODE 

The Induro 145 incorporates a Voltage Reduction Device. This device is designed to 

improve operator safety by reducing the voltage across the welding leads to a safe level 
whenever the machine is not welding. 

There are two safe modes: 

• 

Full  safe

  –  the  output  drops  to  a  safe  voltage 

0.2

  seconds  after  welding  stops. 

The  output  then  switches  back  to  the  welding  voltage  when  the  resistance  from  the 
electrode to the workpiece falls below 200 ohms.   

The Green VRD Safe LED is continuously lit to indicate when the unit is in Full Safe 
mode. 

• 

Tack Weld Mode

 – the output drops to a safe voltage 

seconds after welding stops. 

The output then switches back to the welding voltage when the resistance from the 
electrode to the workpiece falls below 200 ohms. This mode should only be selected if 
performing a series of short welds in succession, and difficulty is experienced in 
starting the arc.  
The Green VRD Safe LED blinks to indicate when the unit is in Tack Weld Mode.  
This mode should only be selected when working in an “environment  without 
increased hazard of electric shock.” For further information, ref er WTIA Tech Note 7. 

 

To  select  Tack  Weld  Mode,  press  the  Weld  Mode  button  three  times  immediately  after 
turning on the machine. The Induro defaults to Full Safe Mode each time it is switched on.  

 

SLEEP MODE 

The Induro 145 goes into “sleep mode” when not u sed for more than 10 minutes. This is a 
low power consumption mode which includes shutting down the fan.  

As  soon  as  the  operator  attempts  to  strike  an  arc or if any button is pressed, the Induro 
145 automatically “wakes up” in the mode in which it was last  used. 

Sleep mode is indicated by the currently selected weld mode LED blinking slowly, with all 
other LEDs being off.

 

6. CONNECTION TO ELECTRICAL MAINS POWER SUPPLY 

The INDURO 145 is supplied with a 15 Amp Heavy Duty mains power supply cable. 

This cable must only be connected to a correctly installed 15 Amp GPO (General Purpose 
Outlet).  The  plug  and  GPO  are  both  identified  by  a  wide  Earth  pin,  which  is  intended  to 
prevent the plug being inserted into a standard 10 Amp GPO. If it becomes necessary to 
replace the mains power supply cable, use only a cable with equivalent current rating.  

The recommended Supply Circuit Breaker rating is 25 Amps.   

If it is necessary to use an extension power supply cable, ensure that it is rated for a 

minimum of 15 Amps. Voltage drop which will occur over long lengths of cable will reduce 
the maximum welding current available from the equipment.  

As noted previously, it is not recommended that the INDURO 145 be powered from 

small  engine-driven  generator  sets  unless  they  have  adequate  voltage  regulation  due  to 
the peaks of supply voltage which can occur with some equipment of this type. Excessive 
voltage peaks can damage the circuits of the welder. 

Содержание INDURO 145

Страница 1: ...11 Head Office and International Sales 5 Allan Street Melrose Park South Australia 5039 Telephone 08 8276 6494 Facsimile 08 8276 6327 www weldingindustries com au info weldingindustries com au OWNERS...

Страница 2: ...in supplying the correct parts SAFETY Before this equipment is put into operation the SAFE PRACTICES section at the back of the manual must be read completely This will help to avoid possible injury d...

Страница 3: ...d with ease in all positions vertical up or down The smooth forceful arc makes it an ideal electrode for all general mild steel applications Austarc 13S Classification E4113 A smooth running electrode...

Страница 4: ...TIG torch with starter kit adaptor argon flow gauge regulator 3 SPECIFICATIONS Primary Voltage 240 Volts AC 10 50 60 Hz Maximum Primary Demand 28 Amp Rated Input Current 16 5 Amp Welding Current Rang...

Страница 5: ...ungsten Arc Welding Mode is selected vi OVER TEMPERATURE INDICATOR This LED is illuminated if any internal thermal protection devices have operated vii VRD SAFE MODE INDICATOR When lit steadily this L...

Страница 6: ...h time it is switched on SLEEP MODE The Induro 145 goes into sleep mode when not used for more than 10 minutes This is a low power consumption mode which includes shutting down the fan As soon as the...

Страница 7: ...G It is important to select the electrode polarity in accordance with the manufacturers recommendations for that electrode Most common electrodes are operated with the electrode at positive polarity a...

Страница 8: ...the arc initiates lift the electrode slightly away aiming to establish an arc length of approximately 3mm As the electrode end is consumed feed the electrode into the arc in order to maintain arc len...

Страница 9: ...rate should be set in the range 2 5 litres min Tungsten electrodes for DC GTAW should be 1 2 Thoriated or Witstar This type will provide the best arc initiation arc stability and tip shape retention...

Страница 10: ...le it can be transferred to the work piece Use of a copper striking plate can be used to avoid electrode contamination The electrode can also be contaminated by contact with the filler rod A contamina...

Страница 11: ...low of the welding current The INDURO 145 welding power source incorporates an in built protection device which will trip if the unit is overloaded In this event the machine will not deliver welding c...

Страница 12: ...Page 12 INDURO 145 OWNERS MANUAL FIGURE 5 INDURO 145 CIRCUIT DIAGRAM...

Страница 13: ...2 Output Socket 25mm Dinsel 10 1 MC100 30 15A Primary Supply Cable 15 A Plug 11 1 M0004 Primary Cable Grip 12 1 M0005 Primary Cable Nut 13 1 MC100 10N Power Control PCB includes 1 E0010 Relay 14 1 MC1...

Страница 14: ...Page 14 INDURO 145 OWNERS MANUAL 6 7 8 10 11 12 13 1 15 14 21 22 16 18 20 17 19 5 23 4 3 9 FIGURE 6 INDURO 145 PARTS DIAGRAM...

Страница 15: ...ken pitted or spattered Recommended shade filter lens Amps TIG MMAW MIG Pulsed MIG 0 100 10 9 10 12 13 100 150 11 10 10 12 13 150 200 12 10 11 11 12 12 13 200 300 13 11 12 13 12 13 300 400 14 12 13 14...

Страница 16: ...nt energy of the arc can also decompose trichlorethylene and perchlorethylene vapours to form phosgene Do not weld or cut where solvent vapours can be drawn into the welding or cutting atmosphere or w...

Страница 17: ...depending on the combustible s solubility followed by purging and inerting with nitrogen or carbon dioxide and using protective equipment as recommended in AS 1674 1974 Water filling just below workin...

Отзывы: