11
10
Fig 1 Weldmatic 180 Controls
1 Control Panel
2 Euro Gun/Cable Connector
3 Positive Welding Output Terminal
4 Negative Welding Output Terminal
5 Polarity Selection Cable
6 m/min Indicator
When this light is on the Digital Display (12)
is indicating the selected wire speed in
metres per minute (MIG Mode).
7 Amps Indicator
When this light is on the Digital Display
(12) is indicating the selected Amps (Stick
or TIG Mode).
8 Power On Indicator
9 Over Temperature Indicator
This light is on if the machine overheats
or mains voltage is too high or low – the
machine will prevent weld output until the
machine has cooled down or mains voltage
returns to normal. Welding output can then
recommence.
10 VRD Safe Indicator
This light is on when the machine is in Stick
Mode (MMAW) and the output voltage is
reduced to a safe level, in accordance with
AS1672.2 2007 Category C.
4 CONTROLS
2
3
5
4
11
12
13
14
7
6
15
16
17
1
8
9
10