WI-PMS310GF-Alien-I QSG

                                                     Page 1 of 21 

                

 

 

 

 

 

 
 

 

 

WI-PMS310GF-Alien-I

 

8GE + 2 SFP 
Layer 2 Managed PoE Industrial Switch  

 

 

Quick Start Guide 

      

 

 

                          V2101 

Содержание WI-PMS310GF-Alien-I

Страница 1: ...WI PMS310GF Alien I QSG Page 1 of 21 WI PMS310GF Alien I 8GE 2 SFP Layer 2 Managed PoE Industrial Switch Quick Start Guide V2101...

Страница 2: ...s 6 6 2 Alarm Connections 7 6 3 Other 7 7 Mounting Options 8 8 Configuration 9 8 1 Accessing the Configuration Interface 9 8 1 1 Graphical User Interface 9 8 1 2 Command Line Interface 10 8 2 Saving C...

Страница 3: ...Console interfaces This document supplements the Wi TeK Managed Industrial PoE Switch User Manual available for download from http www wireless tek com Uploads download 1583371174 pdf 2 Package Conten...

Страница 4: ...ching V1 On DC 37 to 57 V Power applied to V1 input V2 On DC 37 to 57 V power applied to V2 input or DC 12 to 57 V power applied to 4 2 RJ45 LEDs LED State Status Off No network link Giga Green Link E...

Страница 5: ...uto Active Auto selection Off 48V PoE RJ45 3 8 LAN 100 1000 bps Ethernet connection POE Out 2 Pair Pins 4 5 7 8 Software selectable Off 24 V Active 48 V Active 802 3af 15 W max 48 V Active 803 3at 30...

Страница 6: ...nel 6 1 DC Inputs LED Input Comment V1 and V2 Nominal 48 V DC 37 57 VDC 8A max One or both can be active allowing redundant power supplies V3 12 to 57 VDC 10A max An alternative to V2 Wide voltage ran...

Страница 7: ...r High Level Alarm is triggered if voltage above 5V max 57V AL AL This is a relay connection Options are Close Always Closed Normally Closed Open if Alarmed Normally Open Closed if Alarmed Impulse Rep...

Страница 8: ...WI PMS310GF Alien I QSG Page 8 of 21 7 Mounting Options Use the built in DIN rail or Wall mount options...

Страница 9: ...a console cable 8 1 1 Graphical User Interface For full details download this document http www wireless tek com Uploads download 1583371174 pdf When in Factory Reset state the Switch is set to use t...

Страница 10: ...pdf https ubwh com au documents WI TEK_CLI_POE pdf additional CLI commands for POE switches See an example session below with many lines deleted for clarity Username admin Password admin Switch Exec c...

Страница 11: ...ing Current Configuration Configuration changes are not permanent unless saved To preserve a configuration change to be used on the next boot up save the current configuration using the System Configu...

Страница 12: ...ter this has been done consult the DHCP server s list of leases to learn the IP address of the device 1 Select the IP Basic Configuration IP Address Configuration menu selection 2 Set Line Item to 1 S...

Страница 13: ...up By default the Simple Network Time Protocol SNTP client is disabled To enable 1 Select the System Configuration SNMP Configuration menu selection 2 Set Enable Status to Enable Set the Time Zone Ent...

Страница 14: ...ic Information menu option You should see the correct time If the time is incorrect that indicates the Switch is unable to connect to the Internet Start by checking the IP Basic Configuration settings...

Страница 15: ...enable apply TACACS authentication management login to the switch will ONLY use TACACS Only save the configuration after confirming you can still login 1 Setup a TACACS server accessible by the switc...

Страница 16: ...enable des tColoimj9QXZc 2 Select the AAA Configuration Tacacs Configuration menu option and setup similar to as below and click Apply 3 In a new browser window go to the URL of your switch and confir...

Страница 17: ...WI PMS310GF Alien I QSG Page 17 of 21 8 5 2 802 1x EAP The default switch behaviour can be changed such that devices e g PCs plugged into specified ports have no network connectivity until authorized...

Страница 18: ...mation Base MIB definition files are available from https ubwh com au documents WiTek MIBs zip In addition the Switch can send alerts to a TRAP server Shown below are some example screen captures from...

Страница 19: ...WI PMS310GF Alien I QSG Page 19 of 21 Figure 2 Interface Table Query Figure 3 Example Received TRAP messages...

Страница 20: ...is critical Healing ring recovery time less than 50 millisec Between 3 30 switches inclusive Easy setup To use Fast Ring Use Firmware version WI PMS310GF Alien I 5 1 1 or newer Use SFP ports only to l...

Страница 21: ...no firmware updates 9 1 Update using GUI 1 Select the IP Basic Configuration File Upload menu selection 2 Click Choose file and select the xx img file downloaded in section 8 7 3 Click Upload 4 Wait u...