background image

Specifications

2

Model Number

ARC-12D

ARC-12H

Cooling Capacity

12,000 BTU/hr

12,000 BTU/hr

Heating Capacity (1)(2)

N/A

12,000 BTU/hr

Power Consumption

950W / 8.4A

950W / 8.4A

Humidity Removal Capacity

65 Pts. / Day

65 Pts. / Day

Recommended room size*

400 sq. ft.

400 sq. ft.

Power Supply

115V / 60Hz / 1 Phase

115V / 60Hz / 1 Phase

Compressor

Rotary

Rotary

Refrigerant

R-22

R-22

Fan Speed

2

2

Timer

1-12 hours

1-12 hours

Thermostat

62

°

F - 90

°

F

62

°

F - 90

°

F

Net Weight

65 lbs.

68 lbs.

Dimensions

16"W x 17"D x 30"H

16"W x 17"D x 30"H

Working Temperature

Cooling: 62

°

F to 110

°

F

Cooling: 62

°

F to 110

°

F

Heating: 41

°

F to 81

°

F

REMARKS:

1.  The data may vary, please refer to the rating label on the back of the unit.

2.   The above conditions are measured at: 

Cooling - Indoor:  RT 81

°

F, RH 60%

Heating - Indoor:  RT 68

°

F, RH 60%

* Uninsulated rooms such as sunrooms, garages, or attics should be less than 400 sq. ft.

11

Troubleshooting

Содержание SNO ARC-12D

Страница 1: ...he expiration of the warranty the cost of labor and parts will be the responsibility of the original owner of the unit THISWARRANTY DOES NOT COVER Acts of God such as fire flood hurricanes earthquakes...

Страница 2: ...the unit in the recommended room size refer to SPECIFICATIONS Do not locate the air conditioner where furniture or other objects can obstruct the airflow Keep blinds curtains closed during the sunnie...

Страница 3: ...nnect the unit to the power source Make sure the unit is connected to a correctly grounded power supply refer to the rating label located at the back of the unit An opening in a window or wall is requ...

Страница 4: ...ng mode the compressor will switch off if the room temperature is HIGHER than the one set the fan keeps working at the set level When the room temperature drops 5 F below the chosen temperature heatin...

Страница 5: ...play your set temperature At this time the green indicator will light under ST Set Temperature Once the temperature up or down buttons is released the window will return to displaying the ambient temp...

Страница 6: ...l Water indicator should be off now 7 Replace the drain knob By Water Tube Continuous Drainage 1 Remove the drain knob and rubber plug and keep them for future use 2 Connect a suitable water tube of 3...

Страница 7: ...rigerant R 22 R 22 Fan Speed 2 2 Timer 1 12 hours 1 12 hours Thermostat 62 F 90 F 62 F 90 F Net Weight 65 lbs 68 lbs Dimensions 16 W x 17 D x 30 H 16 W x 17 D x 30 H Working Temperature Cooling 62 F t...