background image

ONE YEAR LIMITED WARRANTY 

This WHYNTER product is warranted to the original owner, purchased from an authorized Whynter dealer within 

the 48 U.S. continental states, for one year from the original purchase date against defects in material and work­

manship under normal residential usage.  Should your WHYNTER product prove defective within one year from 

the date of purchase, contact Whynter's Customer Support team with the serial number and proof of purchase to 

make a warranty claim.  A Return Authorization number must be issued before returning any parts or products. 

Parts  or  products  received  without  a  Whynter  issued  Return  Authorization  number  will  be  refused.  Under  this 

warranty, Whynter will repair or replace any parts found defective with new or remanufactured parts or exchange 

the defective product with a new, refurbished, or remanufactured product at our discretion. All defective products 

and parts covered by this warranty will be repaired or replaced on a mail-in basis to Whynter's Service Center. 

This warranty is not transferable.  After the expiration of the warranty,  the cost of labor and parts will be the re­

sponsibility of the original owner. 

Return freight is prepaid by Whynter within two months of purchase. After two months to one year, the customer 

will be responsible for the return freight cost to Whynter's Service Center. Please package the product carefully 

in its original packaging to avoid damage in transit. Whynter is not responsible for damage resulting from shipper 

mishandling or improper packaging.  Please retain the original box and packaging materials. 

THIS 

WARRANTY 

DOES 

NOT 

COVER: 

Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.

Improper power supply such as power surge, low voltage, defective household wiring or inadequate fuses.

Use in commercial or industrial applications.

Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in material

or workmanship.

Damage caused by consumer misuse, tampering, lack of maintenance or failure to follow the care and special handling

provisions in the instructions.

Damage to the finish of the case, or other appearance parts caused by wear.

Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.

Removal,  Replacement Packaging,  Freight and Insurance cost for the warranty service.

Products sold AS  IS or from an unauthorized reseller.

Products that have had their serial numbers removed or defaced.

DISCLAIMER 

OF 

IMPLIED WARRANTIES; LIMITATION 

OF 

REMEDIES 

CUSTOMER'S SOLE AND  EXCLUSIVE  REMEDY  UNDER  THIS  LIMITED  WARRANTY  SHALL  BE  PRODUCT  REPAIR OR RE­

PLACEMENT 

AS 

PROVIDED  HEREIN.  CLAIMS 

BASED 

ON  IMPLIED  WARRANTIES,  INCLUDING  WARRANTIES  OF MERCHANTA­

BILITY  OR  FITNESS  FOR 

PARTICULAR  PURPOSE,  ARE  LIMITED  TO  ONE  YEAR OR THE SHORTEST PERIOD ALLOWED BY 

LAW,  BUT NOT 

LESS 

THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES 

SUCH 

AS 

PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WAR­

RANTY OR ANY IMPLIED WARRANTY. 

SOME STA TES 

AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIM/TA TION OF INCI­

DENTAL OR CONSEQUENTIAL 

DAMAGES, 

OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, 

SO 

THESE LIMITA­

TIONS OR  EXCLUSIONS MAY NOT APPLY TO YOU.  THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY 

ALSO 

HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE. 

The warranty, product contents and specifications are subject to change at any time without notice; 

please refer to www.whynter.com for the most current information. 

To register your warranty, please visit www.whynter.com and fill out the online Warranty Registration 

form. Please be sure to include a copy of your purchase invoice. 

To obtain service or information, contact Whynter LLC via email at [email protected] or call 

866-WHYNTER (866-949-6837).

Product contents and specifications may change without notice. 

Copyright© 2020 Whynter LLC 

WWW.WHYNTER.COM 

14 

Содержание RPD-551EWP

Страница 1: ... Dehumidifier with Pump Model RPD 551 EWP INSTRUCTION MANUAL IHi lriliM Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference ...

Страница 2: ...tion removal and collecting the condensation water in the internal water bucket or draining through a drain hose Please keep this user manual in a safe place for future reference This symbol on the product or its packaging indicates that the appliance can not be treated as normal domestic trash but must be handed in at a collection point for recycling electric and electronic appliances Your contri...

Страница 3: ...2 I SAFETY PRECAUTIONS 4 II INTRODUCTION 5 Ill PARTS AND CONTROLS 6 IV OPERATION INSTRUCTIONS 7 8 V CONTINUOUS DRAINAGE 9 VI MAINTENANCE 10 VII TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 11 VIII TROUBLESHOOTING 12 13 WARRANTY INFORMATION 14 3 ...

Страница 4: ...d to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multiple socket Do not use multiple socket or of an extension cord as it may overheat and become a risk of fire Make sure the plug is clean before usage Do not turn this appliance on and off...

Страница 5: ...47 6 lbs 980 ...

Страница 6: ...and actual humidity on the right side The left LED display will change when timer function is acti vated and the user desired humidity level can be manually set and seen on the right LED display The humidity level can be set within a range of 30 to 90 RH Relative Humidity in 5 increments This can be controlled by pressing the UP or DOWN arrows C F SELECTOR Temperature conversion can be changed fro...

Страница 7: ... the set RH is reached or when the water bucket is full When the water bucket is full the Bucket Full indication lamp will light up and the dehumidifier will stop operating Remove the water in the bucket with two hands then place the water bucket back to it s proper position the machine will start operating again This light will also illuminate when the bucket is removed or not properly inserted D...

Страница 8: ...des of the appliance for good air circulation and 20 or more above the appliance NOTE 10 or more II II II II II 1O or more Air Intake I 10 or more 1 1 1 1 1 11 1 1 I 1O or more I I 1 1 iu t I ccccccc____ c J Dehumidifiers working in a basement will have little or no effect on adjacent enclosed rooms such as closets unless there is enough circulation of air in and out of the enclosed area If the ap...

Страница 9: ...his dehumidifier also comes standard with a 3 ft drain hose To use gravity to drain your portable dehumidifier it must be installed on a level surface or at least 12 inches above the ground on a sturdy table or shelf unit When using the function of continuous drainage the hose must be placed horizontally below the drainage hole Avoid uneven ground and folding the hose 1 You can use the supplied dr...

Страница 10: ...not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently it is recommended to clean the air filter at least once every two weeks Remove the bucket and pull filter downwards Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt Rinse the air filter under warm or cold runn...

Страница 11: ...ily room If your home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity inside your home and a good idea in general if your home has such underlying problems as a leaky foundation walls or inade quate ventilation or if you live in a humid area By keeping the ...

Страница 12: ...iance must be placed in a space midifier is blocked Air grill may that does not restrict air flowing into the be dirty rear coil or out of the front grill Continuous mode is on Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but Humidity setting RH is too Set the humidity level to a lower RH the room is not dry enough high We recommend setting the RH t...

Страница 13: ...has an open circuit or humidity is less than 30 90 RH Humidity Sensor has short circuit or humidity is higher than 90 Lo Temperature is lower than 32 F or temperature sensor has an open circuit Hi Temperature is higher than 122 F or temperature sensor has a short circuit 13 ...

Страница 14: ...le in the possession of a consumernot caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to the product by anyone other than authorized by themanu...

Отзывы: