5. Timer Button

Press to activate the Timer delay feature, in conjunction with the Timer Control Buttons. 

Timer Delay Switch Off

When the appliance is ON, press the Timer button to activate Auto

-

stop function and the Timer OFF

light will come on. Set the desired time delay OFF hours by pressing the  and  buttons. The time
increments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance switches off.
To cancel the delayed switch off function, set the time to 

“00” 

or turn off the appliance.

Timer Delay Switch On

When the appliance is OFF, press the Timer button to activate Auto

-

start function and Timer ON light

will come on. Set the desired time delay ON hours by pressing the  and  buttons. The time incre-
ments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance turns on. To can-
cel the delayed switch on function, set the time to 

“00” 

or turn off the appliance.

Timer Delay Switch On and Off Sequence

When the appliance is OFF, press the Timer button to activate Auto

-

start function and Timer light ON

will come on. Set the desired time delay ON hours by pressing the  and  buttons. Once Timer Delay 
Switch On is placed, press the Timer button again to activate Auto

-

stop function and the Timer OFF 

light will come on. Set the desired time delay OFF hours by pressing the  and  buttons. When the 
delay time set has elapsed, the appliance switches off. To cancel the delayed switch off function, set 
the time to 

“00” 

or turn off the appliance.

 

6. Humidity /Timer Control Buttons

Humidity Set Control Buttons

The humidity level can be set within a range of 35%RH(Relative Humidity) to 85%RH in 5% increments. For
lower humidity level, press the  button and set to a lower RH percentage value. For higher humidity level,
press the  button and set to a higher RH percentage value. Once the RH% is set, the set RH% will stay on
the display for about 5 seconds then it will revert back to current RH%.

Timer Set Control Buttons

If Timer Button is pressed, use the

and  buttons to set the Auto Start and Auto Stop time from 0.0 hour to 

24 hours.

 

7. Power Button

Press to turn the dehumidifier on and off

 

Energy Saver

 

When the unit is running on normal operation, once the RH% is reached, the fan will still run continuously to avoid 
high start

-

up amperage which makes the unit energy

-

efficient . Please note that the fan may run continuously or 

shut off intermittently depending on the RH% and set humidity.

 

Содержание RPD-506EWP

Страница 1: ...roper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model RPD 506EWP INSTRUCTION MANUAL Whynter 50 Pint Portab...

Страница 2: ...be obtained from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance...

Страница 3: ...SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 1...

Страница 4: ...adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multip...

Страница 5: ...umidifier Do not cover the air intake and outlet Do not place the appliance in front of curtains or drapes to ensure they do not obstruct the air intake Keep curtains blinds or drapes closed during th...

Страница 6: ...uous Gravity Drain hose 2 16 5 ft pump drain hose 3 Power Cord Buckle Power Cord Buckle Installation For easy storage install the power cord buckle to the rear of the unit Once installed the power cor...

Страница 7: ......

Страница 8: ...pressing the and buttons Once Timer Delay Switch On is placed press the Timer button again to activate Auto stop function and the Timer OFF light will come on Set the desired time delay OFF hours by...

Страница 9: ...isplay The display screen shows a number of different indications depending on the selection function Shows the set relative humidity level from 35 RH to 85 RH Once the RH is set the set RH will stay...

Страница 10: ...ION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in proper position 3 Make sure filter is installed Fig 1 4 When the unit is turned on for the fi...

Страница 11: ...maximum performance Allow at least 10 of air space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little o...

Страница 12: ...in bucket is restored in its correct position If the unit was turned off prior to the removal of the drain bucket press the Power button to restore operation When you remove the drain bucket do not to...

Страница 13: ...e drain bucket is full NOTE The Pump Indicator Light will flash when there is a failure in the pump operation Please turn off the unit and unplug the power cord and check the following points Clean th...

Страница 14: ...e bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifi er runs efficiently it is recommended to clean the air filter at lea...

Страница 15: ...r home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity in...

Страница 16: ...aced in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but the r...

Страница 17: ...want to remove more moisture set the unit on Continuous operation Empty drain bucket and insert the bucket to the appliance properly The pump indicator light blinks Water pump filter is dirty Water p...

Страница 18: ......

Страница 19: ......

Страница 20: ...in commercial or industrial applications Damage accidental or otherwise to the WHYNTER Beverage Refrigerator while in the possession of a consumer not caused by a defect in material or workmanship Dam...

Отзывы: