5
INTRODUCTION
How it Works
When the dehumidifier is started, the fan begins to pull moisture -laden air across the dehumidifying coils.
The coils condense or draw moisture from the air, and air flows through the top louver into the room as dry,
warm air. Moisture removed from air is collected in a drain bucket on the front of the dehumidifier.
The appliance is designed to operate between 41°F (5°C), and 96°F (35°C). The "Compressor" circuit has
an automatic 3 minute time delayed start if the appliance is turned off and on quickly. This prevents over-
heating of the compressor and possible circuit breaker tripping. Make sure the drain bucket is fitted correctly
otherwise appliance will not turn on.
Energy Saving Guide
This Whynter dehumidifier is an Energy Star rated appliance. Follow the guide below can help to get the
best performance and efficiency from your dehumidifier.
Do not cover the air intake and outlet.
Do not place the appliance in front of curtains or drapes - to ensure they do not obstruct the air intake.
Keep curtains, blinds or drapes closed during the sunniest part of the day.
Close all windows and doors.
Indoor relative humidity should ideally be kept between 35%RH and 60%RH depending on the ambient
temperature.
Make sure the appliance is on a hard and level surface.
To prolong the compressor's life, please wait at least 3 minutes before turning the appliance back on
after shutting it off.
Inspect and keep the air filter clean by cleaning regularly.
Perform routine maintenance.
TECHNICAL DATA
MODEL :
RPD-711DWP
Dehumidifying capacity
70 pints
Drain Bucket capacity
13 pints
EEV (Liters per kW-Hour)
1.85 L/kWh
Power supply
115 V /60 Hz
Maximum power input
915 Watts
Current Consumption
4.6 Amps
Refrigerant
R410A/8.11oz
Air flow M3/H / CFM
335 m3/h / 197 CFM
Fan speeds
2
Unit Dimensions
16.1” W x 11.7” D x 24.3” H
Unit Net Weight
38.6 lbs
Unit Gross Weight
40.3 lbs
Noise Level (dBA)
< 55 dBA