Whynter ARC-148MS Скачать руководство пользователя страница 24

ONE YEAR LIMITED WARRANTY & THREE YEAR 

WAR

RANTY ON COMPRESSOR

This WHYNTER product is warranted to the original owner, purchased from an authorized Whynter dealer within 

the 48 U.S. continental states, for one year from the original purchase date against defects in material and work-

manship under normal residential usage. Should your WHYNTER product prove defective within one year from 

the date of purchase, contact Whynter’s Customer Support team with the serial number and proof of purchase to 

make a warranty claim. A Return Authorization number must be issued before returning any parts or products. 

Parts  or products  received  without  a Whynter issued  Return  Authorization number  will  be refused. Under  this 

warranty, Whynter will repair or replace any parts found defective with new or remanufactured parts or exchange 

the defective product with a new, refurbished, or remanufactured product at our discretion. All defective products 

and parts covered by this warranty will be repaired or replaced on a mail-in basis to Whynter’s Service Center. 

This warranty is not transferable. After the expiration of the warranty, the cost of labor and parts will be the re-

sponsibility of the original owner. 

The compressor of portable air conditioners is warranted for an additional two years after the one year limited 

warranty expires from the date of purchase.  

Return freight is prepaid by Whynter within two months of purchase. After two months to one year, the customer 

will be responsible for the return freight cost to Whynter’s Service Center. Please package the product carefully 

in its original packaging to avoid damage in transit. Whynter is not responsible for damage resulting from shipper 

mishandling or improper packaging. Please retain the original box and packaging materials.  
THIS WARRANTY DOES NOT COVER: 

Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.

Improper power supply such as power surge, low voltage, defective household wiring or inadequate fuses.

Use in commercial or industrial applications

.

Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in material

or workmanship

.

Damage caused by consumer misuse, tampering, lack of maintenance or failure to follow the care and special handling

provisions in the instructions.

Damage to the finish of the case, or other appearance parts caused by wear.

Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.

Removal, Replacement Packaging, Freight and Insurance cost for the warranty service.

Products sold AS IS or from an unauthorized reseller.

Products that have had their serial numbers removed or defaced.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER'S SOLE AND  EXCLUSIVE  REMEDY  UNDER  THIS  LIMITED  WARRANTY  SHALL  BE  PRODUCT  REPAIR OR RE-
PLACEMENT  AS  PROVIDED  HEREIN.  CLAIMS BASED ON  IMPLIED  WARRANTIES,  INCLUDING  WARRANTIES  OF MERCHANTA-
BILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE,  ARE  LIMITED  TO  ONE  YEAR OR THE SHORTEST PERIOD ALLOWED BY 
LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES 
SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WAR-
RANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCI-
DENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITA-
TIONS OR   EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY 
ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE. 

The warranty, product contents and specifications are subject to change at any time without notice; 

please refer to 

www.whynter.com

 for the most current information

.

To register your warranty, please visit www.whynter.com and fill out the online Warranty Registration 

form. Please be sure to include a copy of your purchase invoice. 

To obtain service or information, contact Whynter LLC via email at [email protected] or call 

866-WHYNTER  (866-949-6837).

Product contents and specifications may change without notice. 

Copyright © 2020 Whynter LLC

WWW.WHYNTER.COM 

Содержание ARC-148MS

Страница 1: ...IONER Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future referen...

Страница 2: ...cautions Air Filter Cleaning Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust Hose Installation Cho...

Страница 3: ...the nameplate located on unit have a qualified electrician install the proper receptacle Install the unit on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibra...

Страница 4: ...e the appliance must be disconnected from the supply mains Do not remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Do not run cord un...

Страница 5: ...uction The appliance shall be stored so as to prevent mechanical damage from occurring A warning that the appliance shall be stored in a well ventilated area where the room size corresponds to the roo...

Страница 6: ...rk on the system 2 Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed 3 General...

Страница 7: ...th the room size within which the refrigerant containing parts are installed The ventilation machinery and outlets are operating adequately and are not obstructed If an indirect refrigerating circuit...

Страница 8: ...the copper pipe work If a leak is suspected all naked flames shall be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from th...

Страница 9: ...that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to re use of reclaimed refrigerant It is...

Страница 10: ...re that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning t...

Страница 11: ...ll to ensure proper air conditioning The horizontal louver blade should be at least 20 away from obstacles DO NOT cover the Intakes Outlets or Remote Signal Receptor of the unit as this could cause da...

Страница 12: ...on older units Federal regulations require manufacturers to calculate cooling capacity based on a specific test procedure which was changed just this year Models manufactured before 2017 were tested...

Страница 13: ...ION QUANTITY 1 piece 1 piece 1 piece Window Slider Kit 1 set Clear plastic plug plug is in the upper corner of the plastic bag that holds the user manual 1 piece Foam seal A Adhesive Foam seal B Adhes...

Страница 14: ...emperature 1 C 2 F increments or timer hours 0 24 hours This unit is capable of displaying set temperature in Fahrenheit or in Celsius To convert from one to the other press and hold the Up and Down b...

Страница 15: ...ssory sold separately under the drain area of the lower drain port Remove the bottom drain plug and let the water drain Replace the drain plug and plug in to resume operation Continuous drainage Fig 1...

Страница 16: ...to the necessary length keeping it as short and straight as possible WINDOW KIT INSTALLATION The window kit has been designed to fit most standard vertical and horizontal windows However it may be ne...

Страница 17: ...type Security bracket Screws Foam seal C non adhesive type Foam seal A adhesive type Foam seal B adhesive type Security bracket Screws Foam seal C non adhesive type EXHAUST AND INTAKE HOSE INSTALLATI...

Страница 18: ...s function mode press the MODE button until the DRY indicator light is displayed Please note that when switching function mode there will be an approxi mately 3 minute transition time In dehumidifying...

Страница 19: ...comes on AUTO RESTART In the event of a power outage the air conditioner restarts at the previously set function mode and settings when power is restored CONTROLLING THE AIR FLOW DIRECTION The louvers...

Страница 20: ...ays when remote sends signal to unit 3 ON OFF Display Displays when the unit is turned on and disappears when it is turned off 4 Timer On Indicator Displays when TIMER ON is set 5 Timer Off Indicator...

Страница 21: ...e washable pre This unit has three air filters the washable pre filter activated carbon filter and lower filter Switch off the air conditioner and remove the washable pre filter and activated carbon f...

Страница 22: ...yet because of its time delay The set temperature is too high The internal water reservoir is full and P1 appears on display This unit is designed to work in ambient temperatures of 63 F to 90 F Pres...

Страница 23: ...y The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with a level and hard floor Make...

Страница 24: ...Use in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumernot caused by a defect in material or workmanship Damage caused by cons...