OPERATING YOUR AIR CONDITIONER 

Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of 
the functions. Follow the symbol for the desired function. The unit can be controlled by the unit 
control panel alone or with the remote control. 

 

 
CONTROL PANEL 
 

 
 
 
 
 
 
 
 
 
 

Power Control 

 

Turns the unit on and off. 

Timer 

 

Turns the timer function on and off. 

 

Warning Light 

Condensation water may accumulate in the unit. If 

the internal reservoir becomes full, the warning light 

and the STOP light will come on and the unit will 

stop until the water is drained. 

 

Timer / Temperature Set Control   

Adjusts set thermostat temperature and timer. 

The display temperature is the set temperature.  

NOTE:

 This unit is capable of displaying set 

temperature in Fahrenheit or in Celsius. To convert 

from one to the other, press and hold the Up and 

Down buttons for 3 seconds. 

 

Mode Control 

 

Controls the 4 function modes: COOL, 
DEHUMIDIFYING, FAN ONLY & HEAT. 
Green light: COOL mode 
Purple light: DEHUMIDIFY mode 

Blue light: FAN ONLY mode 

Red light: HEAT mode 

Room Temperature

 

 

Indicates room temperature in 

DEHUMIDIFYING 

mode and FAN ONLY mode.

 

Fan Speed Control 

 

Controls the 3 fan speeds: High, Medium & Low. 
NOTE: Unit does not need to be vented in Fan 
mode 

 

Set Temperature 

 

Indicates set temperature in COOL mode. 

 

 

Содержание ARC-12SDH

Страница 1: ...IONER WITH HEATER co Instruction Manual MODEL ARC 12SDH Congratulations on your new WHYNTER product Please read this Instruction Manual carefully before using this product to ensure proper operation Keep this manual in a safe place for future reference ...

Страница 2: ... ACCESSORIES 6 IDENTIFICATION OF PARTS 7 OPERATING YOUR AIR CONDITIONER 8 INSTALLATION INSTRUCTIONS 9 10 AIR FILTERS INSTALLATION 11 OPERATION INSTRUCTIONS 12 13 WATER DRAINAGE 14 REMOTE CONTROL 15 CARE AND MAINTENANCE 16 TECHNICAL DATA 17 TROUBLESHOOTING 18 19 WARRANTY INFORMATION 20 ...

Страница 3: ...l provide the performance and reliability that we stand for Please keep this user manual in a safe place for future reference DISPOSAL This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash but must be handed in at a collection point for recycling electric and electronic appliances Your contribution to the correct disposal of this produc...

Страница 4: ...turn off the portable air conditioner when cleaning the air filter and transporting Do not turn this unit on and off by plugging and unplugging Always use the ON OFF switch Transport the unit in an upright position only or leave it in an upright position for at least 2 hours before first use Ensure curtains or other objects are not obstructing the air inlet filters Do not bend or crush the exhaust...

Страница 5: ...onditioner At the end of each season all water must be drained from the unit and filter s must be cleaned before storage THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED OPERATING CONDITION MODE ROOM TEMPERATURE COOL Higher than 64 F DRY Higher than 60 F HEAT Higher than 45 F Your portable air conditioner is supplied with a Leakage Current Detection and Inte...

Страница 6: ...IDENTIFICATION OF ACCESSORIES IMAGE ACCESSORY NAME QUANTITY Intake and Exhaust hose 2 pieces Fixture 2 pieces Screws 8 pieces Hose connector 4 pieces Window slider kit 1 set Cover 2 pieces Remote control 1 piece ...

Страница 7: ... g e IDENTIFICATION OF PARTS Front 1 Air vent 2 Control panel 3 Handle Rear 4 Casters 5 Air exhaust hose 6 Evaporator air intake air filter 7 Air intake hose 8 Drain port 9 Power cord 10 Upper Drain Port 10 ...

Страница 8: ...l stop until the water is drained Timer Temperature Set Control Adjusts set thermostat temperature and timer The display temperature is the set temperature NOTE This unit is capable of displaying set temperature in Fahrenheit or in Celsius To convert from one to the other press and hold the Up and Down buttons for 3 seconds Mode Control Controls the 4 function modes COOL DEHUMIDIFYING FAN ONLY HEA...

Страница 9: ...ioner unit hot air must be exhausted out of the room to complete the air exchange of the condenser When the unit is operating in DEHUMIDIFYING or FAN only mode no exhaust is required 1 Pull out about 6 of one end of the hoses 2 Attach the hose connectors to the hoses by turning clockwise 3 Align the slots on the hose connector to the tabs on the air intake outlet and snap the hose to the unit 4 On...

Страница 10: ...dow or sliding door it will cause the window or sliding door not to be properly closed and locked Additional security measurements may be needed 1 Open window approximately 5 2 Adjust the length of the window bars to the same length and width of the opening of the window Cut the window piece if necessary to fit the length of your window 3 Insert the fixtures through the back grooved side of the wi...

Страница 11: ...ich is designed to remove smoke and other odors It is recommended you replace the Activated Carbon Filter every 2 3 months or as needed Follow the steps below to install the filters WARNING NEVER OPERATE THE AIR CONDITIONER WITHOUT THE PRE FILTER 1 Pull up the pre filter frame 2 Remove the Pre Filter from the filter frame 3 Place the Activated Carbon Filter on the Pre Filter 4 Reattached the filte...

Страница 12: ...peeds is not very noticeable when the compressor is on Try setting the unit to Fan only mode you should be able to hear the difference between high and low fan speed settings DEHUMIDIFYING MODE In this mode the air conditioner only dehumidifies the room the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW To activate this function mode pr...

Страница 13: ...justable between 1 24 hours SETTING SWITCH OFF TIMER With the air conditioner operating in any function mode press the Timer Control button Then set the desired time delay OFF hours by pressing the or buttons When the delay time set has elapsed the air conditioner switches off SETTING DELAYED SWITCH ON TIMER With the air conditioner is off press the Timer Control button Then set the desired time d...

Страница 14: ...he portable air conditioner can be switched on by the remote control NOTE Other appliances in the same room controlled by a remote control TV radio stereo etc may cause interferences Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner Remove the batteries if the remote control is not used for long periods INSTALLING BATTER...

Страница 15: ... 2 3 months or as needed WARNING Never operate the air conditioner without the filter in place CLEANING THE AIR CONDITIONER Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner Use a soft damp cloth to wipe the body of the unit Never use harsh chemicals oil based products detergents chemically treated cloths or other cleanin...

Страница 16: ...5v 60Hz Maximum power input 1100 Watts Cooling 1020 Watts Heating Maximum input 10 5 Amps Cooling 9 5 Amps Heating Dehumidifying capacity 96 Pts Day Thermostat 61 F to 89 F Refrigerant R 410A Air flow max 320 m3 Hour Fan speeds 3 H M L Exhaust hose length 49 Unit Dimensions 20 W x 16 5 D x 34 H Unit Weight 71 lbs ...

Страница 17: ...om temperature is outside of the operational tolerances of the unit The Cooling mode is not on The compressor has not turned on yet because of its time delay The set temperature is too high The internal water reservoir is full This unit is designed to work in ambient temperatures of 64 F to 95 F Press the MODE button until the COOL light is shown on the display Give the compressor 3 minutes to tur...

Страница 18: ...s to be drained too often The humidity in the area may very high Possible loose connection Remove the intake hose if the outside humidity is high or it is raining Contact Whynter Service Department Fan speed cannot be changed Fan speed differences are not very noticeable The fan speed difference is not very noticeable when the compressor is on Try setting the unit to Fan only mode you should be ab...

Страница 19: ...p Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer Freight and Insurance cost for the warranty service DISCLAIMER OF IMPLIED WARRANTIES LIMITAT...

Отзывы: