INSTALLATION 

LOCATION 

The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has 
casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not 
attempt to roll the unit over objects. Never place any obstacles around the air inlet or outlet and allow at least 20 
inch of clearance for efficient air-conditioning. 

EXHAUST HOSE INSTALLATION 

When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of 
the condenser. When the unit is operating in DEHUMIDIFY or FAN only mode, installation of the exhaust hose is 
optional. 
 
1.  Pull out about 6” of one end of the exhaust. 
2.  Install the hose connectors onto the exhaust hose by turning 

counter-clockwise. 

3.  Fix one end of the hose connectors by pressing the clip onto 

the rear outlet of the unit. Slide the connector into each slot. 
(Fig. 3) 

4.  Pull the clip to secure the hose connector. 
 

 
Only extend the both hoses to the necessary length. We do not recommend extending more than 9' long. If you 
are interested in purchasing an additional 5’ exhaust hose, please contact [email protected] for retail sales infor-
mation. 

WINDOW KIT INSTALLATION 

When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of 
the condenser. When the unit is operating in fan-only mode, installation of the exhaust hose is optional. 
Your window kit has been designed to fit most standard vertical and horizontal windows (Fig. 4a and Fig. 4b). How-
ever, it may be necessary for you to modify the installation procedures for your window.  
NOTE:  

 

If your window opening is less than the mentioned minimum length of the window slider kit, cut the slide bar with 
holes to fit window opening. Never cut out the holes on the window slide bar. 

 

When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly 
closed and locked. Additional security measurements maybe needed. 

 

Open window approximately 5”. 

 

Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window 
piece if necessary to fit the length of your window.  

 

Insert the fixture through the back grooved side of the window slide bar with hole.  Line up the 4 holes and tight-
en the fixture with 4 screws from the front. (Fig. 4c) 

 

Close the window on the window slide bars. For long term installation, you may screw the window kit into your 
window frame. 

 

Move the unit to the window, extend the hose and attach the other end of the hose to the window slide bar. 

 

Align the slots on the hose connector to the tabs on the fixture and snap the hose to the window slide bar.   

Fig. 3 

Fig. 4a 

Fig. 4b 

Fig. 4c 

Содержание ARC-101CW

Страница 1: ...ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model ARC 101CW INSTRUCTION MANUAL WHYNTER COOLSI...

Страница 2: ...ORMATION 3 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS IDENTIFICATION 6 7 CONTROL PANEL 8 INSTALLATION 9 11 OPERATION INSTRUCTIONS 12 13 REMOTE CONTROL 14 CARE AND MAINTENANCE 15 TROUBLES...

Страница 3: ...cling of this product can be obtained from your local municipal au thority Thank you for choosing the Whynter CoolSize 10000 BTU Compact Portable Air Conditioner Please follow the instructions provide...

Страница 4: ...sh the exhaust hose while in use Always allow at least 20 of clearance around the unit for ventilation Do not use this unit inside closets cabi nets and or cramped spaces between furniture This unit i...

Страница 5: ...atures an ECO FRIENDLY CFC free GREEN R 410A refrigerant and lead free RoHS compliant components TECHNICAL DATA Model ARC 101CW Operational Modes Cool Fan or Dehumidifier Cooling Capacity 10000 BTU De...

Страница 6: ...6 PARTS IDENTIFICATION Handle Control Panel Front Air Vent Louvers Air Filter Air Exhaust Power Cord Air Intake Upper Drain Port Lower Drain Port Condenser Air Intake Casters four...

Страница 7: ...ent Detection and Interruption LCDI plug This plug reduces the risk of fire due to arcing faults in the power supply cord Please follow the instructions below to ensure that LCDI plug works properly 1...

Страница 8: ...0 24 hours This unit is capable of displaying set tempera ture in Fahrenheit or in Celsius To convert from one to the other press and hold the and buttons for 3 seconds LCD Display In Cool mode shows...

Страница 9: ...nit fully exhausts all condensation automatically in most environments when humidity is less than 70 Areas with more than 70 humidity the self evaporating function can still exhaust about 98 of the mo...

Страница 10: ...t hot air must be exhausted out of the room to complete the air exchange of the condenser When the unit is operating in fan only mode installation of the exhaust hose is optional Your window kit has b...

Страница 11: ...sash and outer window sash Shown in Fig 5d WINDOW KIT INSTALLATION IN A SLIDING WINDOW DOOR Additional accessory sold separately Foam Seal 1 Open window or sliding door for approx imately 5 2 Cut the...

Страница 12: ...tton In cooling mode the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on Try setting the unit to Fan only mode you should be able to hear the differ...

Страница 13: ...vent of a power outage the air conditioner restarts at the previously set function mode and settings when power is restored NOISE LEVEL Portable air conditioners may make sounds that are not familiar...

Страница 14: ...the bottom of the battery housing close the flap once the batteries have been inserted Only use two dry LR03 AAA 1 5V Batteries included in the remote control Always change both batteries at the same...

Страница 15: ...3 months or as needed Please contact info whynter com for retail sales information WARNING Never operate the air conditioner without the filter in place CLEANING THE AIR CONDITIONER Always switch off...

Страница 16: ...mperature is too high The internal water reservoir is full and Warning Light appears on dis play This unit is designed to work in ambi ent temperatures of 64 F to 90 F Press Mode Control until the Coo...

Страница 17: ...it is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with a level and h...

Страница 18: ...w the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to the product by anyon...

Отзывы: