background image

 4 

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY 

WHEN USING YOUR AIR CONDIITIONER, FOLLOW THESE BASIC 

PRECAUTIONS:

Before the appliance is used, it must be properly positioned and installed as detailed in this manual. 

Do not under any circumstances cut or remove the third (ground) prong from the power cord

Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an extension cord or
power strip

The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker
for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power
source

It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner

Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air condition-
er

To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other
steamy or wet areas

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other applianc-
es

Do not repair, disassemble and/or modify the unit by yourself

Always turn off the portable air conditioner when cleaning the air filter, and transporting

Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch

Transport the unit in an upright position only, or leave it in an upright position for a minimum of 4 hours before
first use.

Ensure curtains or other objects are not obstructing the air inlet filters

Do not bend or crush the exhaust hose while in use

Always allow at least 20” of clearance around the unit for ventilation. Do not use this unit inside closets, cabi-
nets and/or cramped spaces between furniture

This unit is optimized to operate in an ambient temperature of 64°F – 90°F

This unit must be installed in an area protected from the element, such as wind, rain, water spray or drips

The unit should not be located next to ovens, grills or other sources of high heat

Always place the unit on even and hard and level surface

Do not sit or place objects on the unit

Do not allow children to climb, stand or hang on the appliance. The air conditioner could tip over and get dam-
aged and/or seriously injure somebody

Keep fingers out of the air intakes and air outlets

The appliance is an electrical appliance. To avoid injury from electrical shock do not operate it with wet

 

hands,

while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet condi-tions

When positioning or moving the appliance, ensure it is not turned upside down or greater than 45° or more off
level

This appliance is designed for household, non-commercial use only. Any other use will void the warranty

Do not plug into the power outlet before set up is completed

Do not operate this unit without the air filter(s)

Do not use harsh chemicals to clean the filter(s). Dry thoroughly before inserting the filter(s) into the unit

Do not add extra length to the exhaust hose by more than a total length of 9’. This will reduce the cooling effi-
ciency of the portable air conditioner

At the end of each season, all water must be drained from the unit and filter(s) must be cleaned before stor-
age

SAFETY PRECAUTIONS 

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED. 

Содержание ARC-122DHP

Страница 1: ...peration please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model ARC 122DHP INSTRUCTION MANUAL WHYNTER ELITE 12 000 BTU DUAL HOSE DIGITAL PORTABLE AIR CONDITIONER WITH HEAT AND DRAIN PUMP ...

Страница 2: ...TION 3 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS IDENTIFICATION 6 7 CONTROL PANEL 8 INSTALLATION 9 10 OPERATION INSTRUCTIONS AND TIPS 11 13 REMOTE CONTROL 14 CARE AND MAINTENANCE 15 TROUBLESHOOTING 15 16 WARRANTY INFORMATION 17 ...

Страница 3: ...cling of this product can be obtained from your local municipal au thority Thank you for choosing the Whynter 12 000 BTU Dual Hose Digital Portable Air Conditioner Please follow the instructions provided in this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air condi tioner offers you We trust that your ...

Страница 4: ...crush the exhaust hose while in use Always allow at least 20 of clearance around the unit for ventilation Do not use this unit inside closets cabi nets and or cramped spaces between furniture This unit is optimized to operate in an ambient temperature of 64 F 90 F This unit must be installed in an area protected from the element such as wind rain water spray or drips The unit should not be located...

Страница 5: ...es over a single hose unit A dual hose portable air conditioner will cool a room faster and will help minimize negative air pressure situation in the room If the outside temperature is much higher or more humid than the room the intake hose can be detached and the unit will l function as a single hose unit TECHNICAL DATA Model ARC 122DHP Operational Modes Cool Heat Fan or Air Conditioner Cooling C...

Страница 6: ...IDENTIFICATION Handle Control Panel Front Air Vent Louvers Casters four Air Filter Air Exhaust large hose Power Cord Air Intake Upper Drain Port Lower Drain Port Air Intake small hose Built in drain pump outlet ...

Страница 7: ...Window Kit with tab cut outs Storage Cover 1 piece Intake hose small 1 piece 1 piece 1 piece 1 piece 1 piece 1 Large Slide Locking Exhaust Hose Connector to unit 1 Small Slide Locking Intake Hose Connector to unit 1 Small Intake Hose Connector to Window Kit with tab cut outs Carbon Filter 1 piece Optional Intake filter sold separately 1 piece Note Please visit whynter com for optional accessories ...

Страница 8: ...ed in Fan Mode Timer Button Press to program Timer Delayed Switch ON or OFF function Timer Temp Set Control Adjusts set temperature 1 C 2 F increments or timer hours 0 24 hours This unit is capable of displaying set tempera ture in Fahrenheit or in Celsius To convert from one to the other press and hold the Up and Down buttons for 3 seconds LED Display In Cool mode shows set temperature in C or F ...

Страница 9: ...tioner stops running and shows a warning light refer to page 8 This warning light indicates that the water condensation needs to be drained using the fol lowing procedures Manual drainage Fig 2a Turn off the unit Carefully roll the unit to a drain location or position a flat container dish or optional drain bucket accessory sold separately under the drain area of the lower drain port Remove the dr...

Страница 10: ...xhaust Slide Locking Hose Connector to one end of the exhaust hose large hose and the Large Exhaust Hose Connector with tab cut outs to the other end of the exhaust hose large hose by turning counterclockwise 3 Install the Small Intake Slide Locking Hose Connector to one end of the intake hose small hose and the Small Intake Hose Connector with tab cut outs to the other end of the intake hose smal...

Страница 11: ...ake hose can be covered with the included cover and it will function like a single hose unit DEHUMIDIFYING ONLY MODE In this mode the air conditioner only dehumidifies the room the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW To activate this function mode press the Mode Control until the Dehumidifying indicator light comes on Please ...

Страница 12: ...me on Set the desired time delay OFF hours by pressing the and buttons The time increments are at 1 hour to up to 24 hours When the delay time set has elapsed the air conditioner switches off To cancel the delayed switch off function press the Timer button or turn off the air conditioner SETTING DELAYED SWITCH ON TIMER With the air conditioner is off press the Timer button The display timer settin...

Страница 13: ...d maintain the set temperature 3 Reduce heat sources Direct sunlight televisions computers and other heat generating appliances work against the air conditioner by introducing heat into the space Close window curtains and blinds to keep direct sunlight out Close doors and windows Keep ovens and stoves off Turn off unused lights Add weather stripping around windows and doors 4 Keep the air filter c...

Страница 14: ... the bottom of the battery housing close the flap once the batteries have been inserted Only use two dry LR03 AAA 1 5V Batteries included in the remote control Always change both batteries at the same time Power Control On Off Fan Speed Control High Medium Low On Off Timer Control In running mode Auto Switch Off In stand by mode Auto Switch On Press Up or Down button to adjust the time setting for...

Страница 15: ...the body of the unit Never use harsh chemicals oil based products detergents chemically treated cloths or other cleaning solutions These could possibly damage the body of the air conditioner Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the air conditioner Clean the air filters Drain the condensed water completely Wrapped the power cord a...

Страница 16: ...emperature is too high The internal water reservoir is full and Warning Light appears on dis play This unit is designed to work in ambi ent temperatures of 64 F to 90 F Press Mode Control until the Cooling indicator light is shown on the display Give the compressor 3 minutes to turn on after the Cooling mode has been selected Set the air conditioner to a lower tem perature It is recommended to set...

Страница 17: ...nit is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with a level and hard floor Make sure the wall outlet and support the required power consumption of the air conditioner and do not use an ex tension cord The unit leaks water The unit is tilted or not leveled The wate...

Страница 18: ...s Use in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumer not caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear ...

Отзывы: